AI Paper Atlas

Research map / 3D vision / Gaussian splatting

Radiative Gaussian Splatting for Efficient X-ray Novel View Synthesis

Yuanhao Cai, Yixun Liang, Jiahao Wang, Angtian Wang, Yulun Zhang, Xiaokang Yang, Zongwei Zhou, Alan Yuille

ECCV 2024 · 3D vision › Gaussian splatting · approach: Regularization and primitive design for 3DGS · 62 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Replace SfM initialization with ACUI (ablation)3DGS for X-ray NVS · X-ray NVS averagePSNR (dB): 37.213 -> 38.872Improved
Replace SfM initialization with ACUI (ablation)3DGS for X-ray NVS · X-ray NVS averagetraining time (s): 1898 -> 1172Improved
Replace RGB SH Gaussian model and rasterization with radiative model and DRR (ablation)3DGS + ACUI · X-ray NVS averagePSNR (dB): 38.872 -> 43.404Improved
Replace RGB SH Gaussian model with radiative model and DRR (ablation)3DGS + ACUI · X-ray NVS averageinference speed (fps): 72 -> 148Improved
Use FDK initialization instead of cuboid ACUI (ablation)X-Gaussian · X-ray NVS averagePSNR (dB): 43.404 -> 43.470No clear effect
Use cuboid ACUI instead of random point initialization (ablation)X-Gaussian · X-ray NVS averagePSNR (dB): 41.329 -> 43.404Improved
Increase number of radiation features N_f from 1 to 16 (ablation)X-Gaussian · X-ray NVS averagePSNR (dB): 38.818 -> 43.404Improved
Increase N_f from 16 to 32 (ablation)X-Gaussian · X-ray NVS averagePSNR (dB): 43.404 -> 43.417No clear effect
Use X-Gaussian novel views as extra projections for FDK in sparse-view CT instead of NAFFDK reconstruction · Sparse-view CT (5 real views)PSNR (dB): 21.28 -> 22.60Improved
Use X-Gaussian instead of NAF for novel view synthesisX-ray NVS · X-ray NVS averagePSNR (dB): 36.942 -> 43.404Improved
Set init interval d to 8 instead of 1 (ablation)X-Gaussian ACUI · X-ray NVS averagePSNR (dB): 42.853 -> 43.404Improved

Earlier methods this paper compares with

Named baselines from earlier accepted papers in this paper's results tables: better than 1 of 1 on most shared results.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy