Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add local transformer (TL) (ablation) | EchoPOSE · MITEA test | 3D Dice (%): 68.20 -> 77.08 | Improved |
| add global transformer (TG) to local transformer (ablation) | EchoPOSE · MITEA test | 3D Dice (%): 77.08 -> 84.32 | Improved |
| add geometric intersection loss (ablation) | EchoPOSE · MITEA test | 3D Dice (%): 84.32 -> 87.52 | Improved |
| add geometric prior (initial standard affine AS) (ablation) | EchoPOSE · MITEA test | 3D Dice (%): 85.94 -> 87.52 | Improved |
| use GHD reconstruction instead of OReX with marching cubes (ablation) | EchoPOSE poses · MITEA test | 3D Dice (%): 69.27 -> 87.52 | Improved |
| apply EchoPOSE pose correction to assumed standard poses before GHD | GHD reconstruction · MITEA test | EF error (%): 13.36 -> 1.44 | Improved |
| add third apical view A3C to A4C and A2C (ablation) | EchoPOSE · MITEA test | 3D Dice (%): 76.00 -> 85.73 | Improved |
| add short-axis apical view SAXA (ablation) | EchoPOSE · MITEA test | 3D Dice (%): 85.73 -> 85.77 | No clear effect |
| add short-axis basal view SAXB (ablation) | EchoPOSE · MITEA test | 3D Dice (%): 85.77 -> 87.52 | Improved |
| use nnU-Net AI segmentations instead of ideal sliced masks | EchoPOSE + GHD · MITEA vs MITEA+AI | 3D Dice (%): 87.52 -> 83.82 | Hurt |
| EchoPOSE + GHD instead of Simpson's biplane on real clinical TTE | LV quantification · Routine TTE | LV volume error (%): 17.15 -> 4.22 | Improved |
Closest papers by meaning
- EchoXFlow: A Beamspace Echocardiography Dataset for Cardiac Motion, Flow, and Function (NeurIPS 2026 · similarity 0.87)
- EchoONE: Segmenting Multiple Echocardiography Planes in One Model (CVPR 2025 · similarity 0.84)
- EchoWorld: Learning Motion-Aware World Models for Echocardiography Probe Guidance (CVPR 2025 · similarity 0.83)
- Self-supervised Learning of Echocardiographic Video Representations via Online Cluster Distillation (NeurIPS 2025 · similarity 0.83)
- PolyPose: Deformable 2D/3D Registration via Polyrigid Transformations (NeurIPS 2025 · similarity 0.83)
- Q-PART: Quasi-Periodic Adaptive Regression with Test-time Training for Pediatric Left Ventricular Ejection Fraction Regression (CVPR 2025 · similarity 0.83)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.