Introduces EchoXFlow, a 666-exam beamspace echocardiography dataset with separable B-mode, Doppler, ECG and dense annotations, plus tooling and three cross-modal/segmentation benchmarks using 2D and 3D U-Nets.
Problem
Public echocardiography datasets are scan-converted B-mode videos with Doppler absent or fused as RGB overlays, so cross-modal learning from native acquisition signals (beamspace, separate Doppler streams) is not possible.
Approach
Release routine-care echo recordings as separable modality-specific streams in probe-centered beamspace geometry, paired with ECG and dense/sparse annotations, and define benchmark tasks (Doppler estimation from B-mode, beamspace vs. Cartesian segmentation) that existing datasets cannot support.
Key results
- 3D U-Net on beamspace input reaches the lowest Task 1 tissue-velocity loss (5.07 cm/s vs 7.76 for temporal-mean baseline).
- 3D U-Net achieves 81.2% Dice on LV segmentation with scan-converted input, versus 45.8% for the temporal-mean baseline.
- For blood velocity (Task 2), 3D U-Net reduces the loss from 29.29 to 24.70 cm/s, a modest ~16% improvement over baseline.
Surprising findings
- Beamspace input won slightly on Doppler tasks while scan-converted input won on segmentation, suggesting input domain should match supervision domain.
- Temporal context was the main driver of cross-modal signal: 2D U-Net gains were much smaller than 3D U-Net gains on Tasks 1 and 2.
Limitations
- Single vendor (GE Vivid E95) at a single hospital; transfer untested.
- Annotations are routine clinical reports with inter-operator variability and non-random missingness.
- Doppler measures only beam-aligned velocity and the Doppler reference contains noise, so the irreducible error is unknown; no CMR validation; cross-sectional only, no diagnostic labels.
Experimental setup
Datasets: EchoXFlow
Benchmarks: EchoXFlow Task 1 tissue velocity EchoXFlow Task 2 blood velocity/power/turbulence EchoXFlow Task 3 LV segmentation
Metrics: Nyquist-wrapped L1 masked L1 Dice %
Baselines: Temporal mean 2D U-Net
Builds on: U-Net Muon
Closest papers by meaning
- Self-supervised Learning of Echocardiographic Video Representations via Online Cluster Distillation (NeurIPS 2025 · similarity 0.86)
- ECHOPulse: ECG Controlled Echocardio-gram Video Generation (ICLR 2025 · similarity 0.86)
- EchoWorld: Learning Motion-Aware World Models for Echocardiography Probe Guidance (CVPR 2025 · similarity 0.86)
- Bidirectional Recurrence for Cardiac Motion Tracking with Gaussian Process Latent Coding (NeurIPS 2024 · similarity 0.84)
- CardioLens: Revealing the Clinical Reality Gap of MLLMs via Multi-Sequence Cardiac MRI Evaluations (NeurIPS 2026 · similarity 0.84)
- Q-PART: Quasi-Periodic Adaptive Regression with Test-time Training for Pediatric Left Ventricular Ejection Fraction Regression (CVPR 2025 · similarity 0.83)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.