atlas

Research map / 3D vision / Human pose estimation

Reconstructing Hands in 3D with Transformers

CVPR 2024 · 3D vision › Human pose estimation · approach: Depth-based hand pose regression · 151 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Presents HaMeR, a fully transformer-based (ViT-H) monocular 3D hand mesh recovery model trained on 2.7M examples from ten hand datasets, plus the HInt 2D keypoint benchmark of in-the-wild hands.

Problem

Monocular 3D hand mesh reconstruction is limited by small, controlled training datasets and weak evaluation on in-the-wild images, where robustness matters.

Approach

Scale both the training data (consolidating ~2.7M examples from multiple 2D/3D hand datasets) and the network capacity (ViT-H backbone with transformer decoder head regressing MANO parameters and camera), with a simple design and 2D reprojection plus adversarial priors.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Use HaMeR instead of the strongest listed baseline3D hand mesh recovery · FreiHANDPA-MPVPE: 5.8 -> 5.7Helped
Use HaMeR instead of the strongest listed baseline3D hand mesh recovery · HO3Dv2AUCJ: 0.835 -> 0.846Helped
Use HaMeR instead of the strongest listed baseline3D hand mesh recovery · HInt New Days, all jointsPCK@0.05: 16.8 -> 49.4Helped
Use HaMeR instead of the strongest listed baseline3D hand mesh recovery · HInt VISOR, all jointsPCK@0.05: 19.1 -> 44.4Helped
Use HaMeR instead of the strongest listed baseline3D hand mesh recovery · HInt Ego4D, all jointsPCK@0.05: 14.7 -> 40.3Helped
Increase training examples by 4× (ablation)HaMeR base design · HInt New Days, all jointsPCK@0.05: 16.9 -> 31.3Helped
Replace ResNet50 with ViT-H (ablation)HaMeR base design · HInt New Days, all jointsPCK@0.05: 16.9 -> 25.9Helped
Combine large training data with the ViT-H model (ablation)HaMeR · HInt New Days, all jointsPCK@0.05: 16.9 -> 49.4Helped
Add HInt training data (ablation)HaMeR · HInt New Days, all jointsPCK@0.05: 49.4 -> 51.7Helped
Add HInt training data (ablation)HaMeR · HInt VISOR, all jointsPCK@0.05: 44.4 -> 56.5Helped
Add HInt training data (ablation)HaMeR · HInt Ego4D, all jointsPCK@0.05: 40.3 -> 47.2Helped

Surprising findings

Limitations

Experimental setup

Datasets: FreiHAND HO3D MTC RHD InterHand2.6M H2O3D DexYCB COCO-WholeBody Halpe MPII NZSL Hands23 New Days VISOR

Benchmarks: FreiHAND HO3Dv2 HInt

Metrics: PA-MPJPE PA-MPVPE AUCJ AUCV F@5mm F@15mm PCK@0.05 PCK@0.1 PCK@0.15

Baselines: FrankMocap METRO Mesh Graphormer HandOccNet MobRecon AMVUR I2L-MeshNet Pose2Mesh

Builds on: HMR2.0 FrankMocap MANO ViT

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy