AI Paper Atlas

Research map / Vision-language and multimodal / CLIP and zero-shot

MedCLIP: Contrastive Learning from Unpaired Medical Images and Text

Zifeng Wang, Zhenbang Wu, Dinesh Agarwal, Jimeng Sun

EMNLP 2022Vision-language and multimodal › CLIP and zero-shotapproach: CLIP training recipes and data curation1,443 citations (OpenAlex)

Adobe

Read the paperPlace an idea next to itCheck your own paper ↗

11measured effects
7improved
2hurt
2mixed

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
decouple images and texts and use semantic matching loss (MedCLIP vs GLoRIA)contrastive pre-training · CheXpert-5x200 zero-shotaccuracy: 0.4328 -> 0.5476 (ResNet)Improved
use MedCLIP-ViT instead of GLoRIAcontrastive pre-training · COVID zero-shotaccuracy: 0.7090 -> 0.8013Improved
add prompt ensemble (ablation)MedCLIP · zero-shot, four datasetsaccuracy: 0.5476 -> 0.5712 (CheXpert-5x200, ResNet); 0.8472 -> 0.8369 (COVID, ResNet)Mixed
add prompt ensemble (ablation)GLoRIA · zero-shot, four datasetsaccuracy: 0.7090 -> 0.5702 (COVID)Hurt
add prompt ensemble (ablation)ConVIRT · zero-shot, four datasetsaccuracy: 0.5184 -> 0.6647 (COVID); 0.4731 -> 0.4647 (RSNA)Mixed
pre-train with 20K samples instead of the full CheXpert (about 200K) as GLoRIAMedCLIP · CheXpert-5x200 zero-shotaccuracyImproved
increase pre-training data to 570K (ablation)MedCLIP · CheXpert-5x200 zero-shotaccuracyImproved
replace baselines with MedCLIP for frozen-encoder fine-tuninglinear classifier · four datasets fine-tunedaccuracy: 0.5370 -> 0.5960 (CheXpert-5x200, vs GLoRIA)Improved
use zero-shot MedCLIP vs its fine-tuned counterpartMedCLIP · COVIDaccuracy: 0.7890 -> 0.8472Improved
use MedCLIP instead of GLoRIA for retrievalimage-text retrieval · CheXpert-5x200Precision@1: 0.47 -> 0.45Hurt
use MedCLIP instead of GLoRIA for retrieval at larger Kimage-text retrieval · CheXpert-5x200Precision@10: 0.46 -> 0.50Improved

Later papers that compared with this method

4 later accepted papers report MedCLIP as a baseline in their results tables; 4 of them report a better number on most of the results they share with it.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy