Research map / Vision-language and multimodal / Multimodal LLMs
Divide and Conquer Radiology Report Generation via Observation Level Fine-grained Pretraining and Prompt Tuning
Yuanpin Zhou, Huogen Wang
Zhejiang University · HiThink Research
Read the paperPlace an idea next to itCheck your own paper ↗
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
On benchmark leaderboards
- MIMIC-CXR leaderboard BLEU-4 0.12 · rank 22 of 36 papers
This paper tried a common change: Add a contrastive loss
add Step 2 calibrated contrastive learning · MIMIC-CXR · CE F1: 0.365 -> 0.376 Improved
What 1,541 accepted papers report for this change
- 1,463 improved
- 27 no clear effect
- 20 mixed
- 31 hurt
- Beyond Looking Up, Try Looking Around: Harmonizing Global Structure and Local Consistency in Optimal Transport for Short Text Clustering ICML 2026 · add contrastive learning · SearchSnippets · ACC: 56.65 -> 80.12Improved
- SleepLM: Natural-Language Intelligence for Human Sleep ICML 2026 · add contrastive objective to captioning (CoCa vs Cap) · sleep event IoU · IoU: 29.2 -> 27.4Hurt
- LIMSSR: LLM-Driven Sequence-to-Score Reasoning under Training-Time Incomplete Multimodal Observations ICML 2026 · add contrastive loss L_con · FS1000 average · Spearman correlation: 0.759 -> 0.789Improved
See this change in detailMatched by the wording of each paper's own result, read by AI from the full text. Papers report gains more often than failures, so this shows what gets published, not the chance a change works.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| use DCRRG instead of PhenotypeCLIP | report generation · MIMIC-CXR | CIDEr: 0.259 -> 0.282 | Improved |
| use DCRRG instead of PhenotypeCLIP | report generation · MIMIC-CXR | ROUGE-L: 0.286 -> 0.284 | No clear effect |
| use DCRRG instead of DCL | report generation · MIMIC-CXR | CE precision: 0.471 -> 0.460 | Hurt |
| add CheXpert data for complementation | DCRRG · MIMIC-CXR | CE F1: 0.376 -> 0.401 | Improved |
| add data balancing in Step 1 (ablation) | DCRRG · MIMIC-CXR | CE F1: 0.354 -> 0.376 | Improved |
| add extra CheXpert data in Step 1 instead of balancing (ablation) | DCRRG · MIMIC-CXR | CE F1: 0.354 -> 0.368 | Improved |
| add Step 1 observation-level pretraining (ablation) | DCRRG · MIMIC-CXR | CE F1: 0.327 -> 0.376 | Improved |
| add Step 2 calibrated contrastive learning (ablation) | DCRRG · MIMIC-CXR | CE F1: 0.365 -> 0.376 | Improved |
| add Step 3 observation description generation (ablation) | DCRRG · MIMIC-CXR | CE F1: 0.371 -> 0.376 | Improved |
| use prompt tuning instead of full fine-tuning in Step 4 (ablation) | DCRRG · MIMIC-CXR | CE F1: 0.376 (PT) vs 0.376 (FFT) | No clear effect |
| add data balancing (ablation) | DCCLIP · CheXpert-5x200 retrieval | P@1: 0.45 -> 0.48 | Improved |
| use DCCLIP encoder pretraining instead of ImageNet | image encoder · CheXpert classification, fine-tuning | AUROC: 87.1 (ImageNet 100%) -> 88.8 (DCCLIP 1%) | Improved |
Earlier methods this paper compares with
Named baselines from earlier accepted papers in this paper's results tables: better than 1 of 1 on most shared results.
- MedCLIP* — MedCLIP: Contrastive Learning from Unpaired Medical Images and Text (EMNLP 2022) · better on 6 of 6 shared results
Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.
Closest papers by meaning
- Bootstrapping Large Language Models for Radiology Report Generation (AAAI 2024 · similarity 0.92)
- LLM-RG4: Flexible and Factual Radiology Report Generation Across Diverse Input Contexts (AAAI 2025 · similarity 0.91)
- MediVLM: A Vision Language Model for Radiology Report Generation from Medical Images (EMNLP 2025 · similarity 0.90)
- Improving the Factual Correctness of Radiology Report Generation with Semantic Rewards (EMNLP 2022 · similarity 0.90)
- Fine-grained Medical Vision-Language Representation Learning for Radiology Report Generation (EMNLP 2023 · similarity 0.90)
- Style-Aware Radiology Report Generation with RadGraph and Few-Shot Prompting (EMNLP 2023 · similarity 0.90)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.