atlas

Research map / Vision-language and multimodal / Human and embodied modeling

MedUnifier: Unifying Vision-and-Language Pre-training on Medical Data with Vision Generation Task using Discrete Visual Representations

CVPR 2025 · Vision-language and multimodal › Human and embodied modeling · approach: Vision-language pretraining · 7 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Proposes MedUnifier, a unified medical vision-language pre-training framework that adds a VQ-VAE-based text-grounded image generation objective to ITC, ITM and ITG losses, trained on MIMIC-CXR.

Problem

Existing medical vision-language pre-training emphasizes feature extraction and cross-modal understanding while neglecting text-grounded visual content generation, which limits multi-modal learning and fine-grained visual detail capture.

Approach

Integrates a hierarchical VQ-VAE image generator with latent adapters into a BLIP-2-style fusion encoder with learnable query embeddings, co-training image generation (TIG) end-to-end with contrastive, matching and text generation objectives using discrete visual representations.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Add TIG to MedUnifier (ablation)MedUnifier · RSNA, SIIM, and COVIDx fine-tuningAUC / accuracy: RSNA: 86.3, 87.1, 88.1 -> 87.6, 88.8, 91.7; SIIM: 87.6, 88.7, 92.3 -> 87.9, 92.5, 94.8; COVIDx: 75.3, 87.5, 92.8 -> 76.8Helped
Add TIG to MedUnifier (ablation)MedUnifier · MIMIC-CXR 5x200 ITRmAP@1: 57.4 -> 60.7Helped
Add TIG to MedUnifier (ablation)MedUnifier · MIMIC-CXR 5x200 TIRmAP@1: 59.6 -> 63.1Helped
Add TIG to MedUnifier (ablation)MedUnifier · MIMIC-CXR 5x200 TIRmAP@5: 68.3 -> 70.8Helped
Add TIG to MedUnifier (ablation)MedUnifier · MIMIC-CXR 5x200 TIRmAP@10: 63.4 -> 64.4Helped
Add TIG to MedUnifier (ablation)MedUnifier · MIMIC 5x200 zero-shotaccuracy: 44.8 -> 50.4Helped
Add TIG to MedUnifier (ablation)MedUnifier · CheXpert 5x200 zero-shotaccuracy: 40.8 -> 43.5Helped
Add TIG to MedUnifier (ablation)MedUnifier · RSNA zero-shotaccuracy: 85.0 -> 82.0Hurt
Add TIG to MedUnifier (ablation)MedUnifier · MIMIC-CXR test setBLEU-4: 11.3 -> 12.9Helped
Add TIG to MedUnifier (ablation)MedUnifier · MIMIC-CXR test setROUGE-L: 29.6 -> 34.0Helped
Add ITM to ITC (ablation)MedUnifier pre-training objectives · MIMIC-CXR 5x200 retrievalmAP@1: 53.7 -> 55.2Helped
Add ITG to ITC and ITM (ablation)MedUnifier pre-training objectives · MIMIC-CXR 5x200 retrievalmAP@1: 55.2 -> 57.4Helped

Surprising findings

Limitations

Experimental setup

Datasets: MIMIC-CXR v2.0.0 RSNA Pneumonia SIIM-ACR COVIDx CheXpert 5x200

Benchmarks: RSNA Pneumonia SIIM-ACR COVIDx MIMIC 5x200 CheXpert 5x200 MIMIC-CXR test set

Metrics: AUROC accuracy mAP@K BLEU METEOR ROUGE-L FID

Baselines: ConVIRT GLoRIA BioViL LoVT MGCA PRIOR MedCLIP REFERS CXR-CLIP R2Gen PTUnifier LLM-CXR

Builds on: BLIP-2 VQ-VAE BERT CLIP

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy