Research map / Label-efficient and robust learning / Semi-supervised learning
A Self-training Framework for Automated Medical Report Generation
Siyuan Wang, Zheng Liu, Bo Peng
The University of Sydney · University College London · Newcastle University
Read the paperPlace an idea next to itCheck your own paper ↗
11measured effects
10improved
1mixed
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
On benchmark leaderboards
- MIMIC-CXR leaderboard BLEU-4 0.182 · rank 3 of 36 papers
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add input noise (Noisy Student) in training (ablation) | REMOTE, 1% labeled · MIMIC-CXR | BLEU-4: 0.103 -> 0.115 | Improved |
| add model noise (Noisy Student) in training (ablation) | REMOTE, 1% labeled · MIMIC-CXR | BLEU-4: 0.093 -> 0.115 | Improved |
| add input noise in training (ablation) | REMOTE, 1% labeled · COVID-19 | CIDEr: 0.192 -> 0.201 | Improved |
| add model noise in training (ablation) | REMOTE, 1% labeled · COVID-19 | CIDEr: 0.178 -> 0.201 | Improved |
| add model noise in training (ablation) | REMOTE, 100% labeled · MIMIC-CXR | BLEU-4: 0.108 -> 0.125 | Improved |
| add input noise in training (ablation) | REMOTE, 100% labeled · MIMIC-CXR | BLEU-4: 0.119 -> 0.125 | Improved |
| add external CheXpert unlabeled images (ablation) | REMOTE, 100% labeled · MIMIC-CXR | BLEU-4: 0.125 -> 0.165 | Improved |
| add all three external unlabeled image sets (RSNA + CheXpert + COVID) (ablation) | REMOTE, 100% labeled · MIMIC-CXR | CIDEr: 0.338 -> 0.497 | Improved |
| add all three external unlabeled image sets (RSNA + CheXpert + COVID) (ablation) | REMOTE, 100% labeled · COVID-19 | CIDEr: 0.269 -> 0.407 | Improved |
| train REMOTE with 1% labeled pairs plus unlabeled images instead of fully supervised XProNet | XProNet · MIMIC-CXR | BLEU-4: 0.105 -> 0.115 | Improved |
| train REMOTE with 1% labeled pairs compared with fully supervised DeltaNet | DeltaNet · MIMIC-CXR | CIDEr: 0.281 vs 0.266 | Mixed |
Closest papers by meaning
- Auto-Encoding Knowledge Graph for Unsupervised Medical Report Generation (NeurIPS 2021 · similarity 0.88)
- MedRAT: Unpaired Medical Report Generation via Auxiliary Tasks (ECCV 2024 · similarity 0.88)
- Automated Generation of Accurate & Fluent Medical X-ray Reports (EMNLP 2021 · similarity 0.87)
- PromptMRG: Diagnosis-Driven Prompts for Medical Report Generation (AAAI 2024 · similarity 0.87)
- Image-aware Evaluation of Generated Medical Reports (NeurIPS 2024 · similarity 0.86)
- DAMPER: A Dual-Stage Medical Report Generation Framework with Coarse-Grained MeSH Alignment and Fine-Grained Hypergraph Matching (AAAI 2025 · similarity 0.85)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.