Research map / Vision-language and multimodal / Human and embodied modeling
MedRAT: Unpaired Medical Report Generation via Auxiliary Tasks
Elad Hirsch, Gefen Dawidowicz, Ayellet Tal
Technion - Israel Institute of Technology
Read the paperPlace an idea next to itCheck your own paper ↗
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
This paper tried a common change: Add a reconstruction / auxiliary loss
add the contrastive auxiliary task · MIMIC-CXR · BLEU-1: 0.271 -> 0.365 Improved
What 1,077 accepted papers report for this change
- 961 improved
- 44 no clear effect
- 21 mixed
- 51 hurt
- OPTION: Optimal Transport–Guided Flow Matching for Incomplete and Unaligned Multi-View Clustering ICML 2026 · add reconstruction loss L_rec · Scene-15 (aligned, 70% missing) · ACC: 32.4 -> 37.5Improved
- Detached Skip-Links and $R$-Probe: Decoupling Feature Aggregation from Gradient Propagation for MLLM OCR ICML 2026 · add R-probe auxiliary loss · OCRBench · score: 714.0 -> 721.0Improved
- Rethinking Time-Series Imputation as Conditional Inference along Temporal Evolution ICML 2026 · add reconstruction loss on observed entries (joint vs missing-only supervision) · ETTh1 10% missing · Masked MAE: 0.2002 -> 0.1658Improved
See this change in detailMatched by the wording of each paper's own result, read by AI from the full text. Papers report gains more often than failures, so this shows what gets published, not the chance a change works.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add local representations to the decoder input (ablation) | MedRAT · MIMIC-CXR | BLEU-1: 0.162 -> 0.365 | Improved |
| add global representation to the decoder input (ablation) | MedRAT · MIMIC-CXR | BLEU-1: 0.316 -> 0.365 | Improved |
| add the contrastive auxiliary task (ablation) | MedRAT · MIMIC-CXR | BLEU-1: 0.271 -> 0.365 | Improved |
| add the classification auxiliary task (ablation) | MedRAT · MIMIC-CXR | BLEU-1: 0.225 -> 0.365 | Improved |
| add shared memory (ablation) | MedRAT · MIMIC-CXR | BLEU-1: 0.343 -> 0.365 | Improved |
| add dropout augmentation of decoder local representations (ablation) | MedRAT · MIMIC-CXR | BLEU-1: 0.295 -> 0.365 | Improved |
| add Gaussian noise augmentation instead of dropout (ablation) | MedRAT · IU X-ray | BLEU-1: 0.333 -> 0.455 | Improved |
| use 1% paired image-report data in addition to unpaired data | MedRAT · MIMIC-CXR | BLEU-1: 0.365 -> 0.390 | Improved |
| MedRAT versus MedCycle on IU X-ray | MedRAT · IU X-ray (zero-shot) | BLEU-4: 0.143 -> 0.129 | Hurt |
Closest papers by meaning
- Unify, Align and Refine: Multi-Level Semantic Alignment for Radiology Report Generation (ICCV 2023 · similarity 0.89)
- DART: Disease-aware Image-Text Alignment and Self-correcting Re-alignment for Trustworthy Radiology Report Generation (CVPR 2025 · similarity 0.88)
- Automatic Radiology Reports Generation via Memory Alignment Network (AAAI 2024 · similarity 0.88)
- DAMPER: A Dual-Stage Medical Report Generation Framework with Coarse-Grained MeSH Alignment and Fine-Grained Hypergraph Matching (AAAI 2025 · similarity 0.87)
- S2D-Align: Shallow-to-Deep Auxiliary Learning for Anatomically-Grounded Radiology Report Generation (AAAI 2026 · similarity 0.87)
- Image-aware Evaluation of Generated Medical Reports (NeurIPS 2024 · similarity 0.87)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
