atlas

Research map / Image generation / Autoregressive and latent generation

Image-aware Evaluation of Generated Medical Reports

NeurIPS 2024 · Image generation › Autoregressive and latent generation · approach: Retrieval and matching with generative features · 1 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Proposes VLScore, a image-aware metric for X-ray report evaluation that scores the triangle area formed by image, generated report, and reference report embeddings in a LIMITR shared space, and introduces a perturbed MIMIC-CXR dataset for metric sensitivity.

Problem

Existing evaluation metrics for generated radiology reports either measure only textual overlap or only a limited set of pathologies (CE metrics), and correlate poorly with radiologist judgment.

Approach

Score report quality using the joint image-report embedding space: the area of the triangle formed by the image, generated report and reference report embeddings (lower area means higher similarity), normalized by a constant C, instead of comparing two texts alone.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Use VLScore instead of RadGraph F1 for metric evaluationmedical report generation evaluation · ReXValKendall τ with radiologist judgments: 0.515 -> 0.718Helped
Remove a pathology sentence rather than an insignificant sentenceVLScore · Perturbed datasetsimilarity score difference: 0.84 -> 0.69; 0.15Helped
Change a pathology location word rather than a non-informative wordVLScore · Perturbed datasetsimilarity score difference: 0.91 -> 0.72; 0.19Helped
Change a pathology severity word rather than a non-informative wordVLScore · Perturbed datasetsimilarity score difference: 0.91 -> 0.79; 0.12Helped
Use triangle area instead of report-report cosine similarity (ablation)VLScore · ReXValKendall τ: 0.555 -> 0.718Helped
Use triangle area instead of minimal bounding sphere (ablation)VLScore · ReXValKendall τ: 0.525 -> 0.718Helped
Use triangle area instead of image-centered cosine similarity (ablation)VLScore · ReXValKendall τ: 0.678 -> 0.718Helped
Use image-centered cosine similarity instead of report-report cosine similarity (ablation)embedding similarity measurement · ReXValKendall τ: 0.555 -> 0.678Helped
Use LIMITR embeddings instead of ConVIRT, BioViL, MedCLIP, or GLoRIA (ablation)VLScore · ReXValKendall τ: 0.526; 0.580; 0.636; 0.698 -> 0.718Helped
Use VLScore rather than BLEU-4 on equivalent normal reports with standardized wordingmedical report evaluation metrics · Perturbed dataset, normal reportsaverage similarity score: 0.15 -> 0.85Helped

Surprising findings

Limitations

Experimental setup

Datasets: MIMIC-CXR ReXVal

Benchmarks: ReXVal perturbed MIMIC-CXR dataset

Metrics: Kendall tau score deltas under perturbations

Baselines: BLEU METEOR ROUGE-L BERTScore CheXpert CheXbert RadGraph F1 ConVIRT BioViL MedCLIP GLoRIA

Builds on: LIMITR RadGraph F1 BERTScore CheXbert

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy