Research map / Vision-language and multimodal / Human and embodied modeling
Automated Generation of Accurate & Fluent Medical X-ray Reports
Hoang T.N. Nguyen, Dong Nie, Taivanbat Badamdorj, Yujie Liu, Yingying Zhu, Jason Truong, Li Cheng
University of Alberta · University of North Carolina at Chapel Hill · Guangzhou University of Chinese Medicine · University of Texas at Arlington
Read the paperPlace an idea next to itCheck your own paper ↗
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add D_states to the enriched disease embedding (ablation) | contextualized model · Open-I | BLEU-4: 0.169 -> 0.217 | Improved |
| add D_topics to the enriched disease embedding (ablation) | contextualized model · Open-I | BLEU-4: 0.187 -> 0.217 | Improved |
| add D_fused to the enriched disease embedding (ablation) | contextualized model · Open-I | BLEU-4: 0.204 -> 0.217 | Improved |
| add D_fused to the enriched disease embedding (ablation) | image-only model · Open-I | BLEU-4: 0.151 -> 0.151 | No clear effect |
| add D_states to the enriched disease embedding (ablation) | image-only model · Open-I | BLEU-4: 0.127 -> 0.151 | Improved |
| add the interpreter (ablation) | contextualized model · Open-I | BLEU-4: 0.217 -> 0.235 | Improved |
| add the interpreter (ablation) | image-only model · Open-I | BLEU-4: 0.151 -> 0.158 | Improved |
| add the interpreter (ablation) | image-only model · Open-I | ROUGE-L: 0.377 -> 0.375 | Mixed |
| add clinical history text (contextualized) to multi-view input | Ours (MV) · Open-I | BLEU-4: 0.164 -> 0.217 | Improved |
| add clinical history text to multi-view input | Ours (MV) · MIMIC-CXR | BLEU-4: 0.144 -> 0.223 | Improved |
| add the interpreter (MV+T to MV+T+I) | Ours (MV+T) · MIMIC-CXR (CheXpert, macro) | F-1: 0.407 -> 0.412 | Improved |
| add the interpreter (MV+T to MV+T+I) | Ours (MV+T) · MIMIC-CXR (CheXpert, micro) | precision: 0.583 -> 0.567 | Hurt |
Closest papers by meaning
- DART: Disease-aware Image-Text Alignment and Self-correcting Re-alignment for Trustworthy Radiology Report Generation (CVPR 2025 · similarity 0.90)
- Image-aware Evaluation of Generated Medical Reports (NeurIPS 2024 · similarity 0.89)
- DAMPER: A Dual-Stage Medical Report Generation Framework with Coarse-Grained MeSH Alignment and Fine-Grained Hypergraph Matching (AAAI 2025 · similarity 0.89)
- From Complexity to Clarity: Transforming Chest X-ray Reports with Chained Prompting (Student Abstract) (AAAI 2025 · similarity 0.88)
- Bootstrapping Large Language Models for Radiology Report Generation (AAAI 2024 · similarity 0.88)
- Automatic Radiology Reports Generation via Memory Alignment Network (AAAI 2024 · similarity 0.88)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
