AI Paper Atlas

Research map / Detection and segmentation / CNN features

Probing Deep Into Temporal Profile Makes the Infrared Small Target Detector Much Better

Ruojing Li, Wei An, Yingqian Wang, Xinyi Ying, Yimian Dai, Longguang Wang, Miao Li, Yulan Guo, Li Liu

TPAMI 2026 · Detection and segmentation › CNN features · approach: Context for hard detection conditions · 26 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add TPro (temporal probe) instead of 1x1xT convolutions (ablation)DeepPro · NUDT-MIRSDT (SNR<=3 subset)probability of detection Pd (x1e-2): 92.44 -> 95.84Improved
add TPro instead of 1x1xT convolutions (ablation)DeepPro · NUDT-MIRSDT-HiNoprobability of detection Pd (x1e-2): 53.21 -> 59.17Improved
add TPro instead of 1x1xT convolutions (ablation)DeepPro · NUDT-MIRSDTfalse alarm rate Fa (x1e-5): 1.96 -> 0.72Improved
increase input length from T=5 to T=40 (ablation)DeepPro · NUDT-MIRSDT-HiNoprobability of detection Pd (x1e-2): 23.14 -> 59.17Improved
increase input length from T=10 to T=20 (ablation)DeepPro · NUDT-MIRSDT-HiNoprobability of detection Pd (x1e-2): 46.44 -> 57.49Improved
increase input length from T=40 to T=80 (ablation)DeepPro · NUDT-MIRSDT-HiNoprobability of detection Pd (x1e-2): 59.17 -> 60.21No clear effect
use 4 SCorMs instead of 1 (ablation)DeepPro · NUDT-MIRSDT-HiNoprobability of detection Pd (x1e-2): 55.12 -> 59.17Improved
increase SCorMs from 4 to 8 (ablation)DeepPro · NUDT-MIRSDT-HiNoprobability of detection Pd (x1e-2): 59.17 -> 59.17No clear effect
add the 2nd and 3rd levels to the 1st level (ablation)DeepPro · NUDT-MIRSDT-HiNoprobability of detection Pd (x1e-2): 53.50 -> 59.17Improved
add spatial-temporal convolutions and keep one level (DeepPro-Plus) (ablation)DeepPro · NUDT-MIRSDT-HiNoprobability of detection Pd (x1e-2): 59.17 -> 76.23Improved
increase STD-ResBlocks from n=2 to n=4 (ablation)DeepPro-Plus · NUDT-MIRSDT-HiNoprobability of detection Pd (x1e-2): 76.23 -> 72.76Hurt
use three levels (DeepPro+S) instead of one level (DeepPro-Plus) (ablation)DeepPro-Plus · NUDT-MIRSDT-HiNoprobability of detection Pd (x1e-2): 76.23 -> 76.52No clear effect

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy