AI Paper Atlas

Research map / 3D vision / Depth and stereo

FreeCam3D: Snapshot Structured Light 3D with Freely-Moving Cameras

Yicheng Wu, Vivek Boominathan, Xuan Zhao, Jacob T. Robinson, Hiroshi Kawasaki, Aswin Sankaranarayanan, Ashok Veeraraghavan

ECCV 2020 · 3D vision › Depth and stereo · approach: Feed-forward 3D reconstruction · 11 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
replace uniform grid pattern with Kronecker-multiplexed pattern (ablation)FreeCam3D · Simulation test, Table 1Lx (mm): 52.1 -> 8.3Improved
replace Kinect pattern with Kronecker-multiplexed pattern (ablation)FreeCam3D · Simulation test, Table 1Lx (mm): 15.8 -> 8.3Improved
replace M-array pattern with Kronecker-multiplexed pattern (ablation)FreeCam3D · Simulation test, Table 1Lz (mm): 15.5 -> 6.1Improved
replace grid pattern with Kronecker-multiplexed pattern (ablation)FreeCam3D · Simulation test, Table 1Lz (mm): 8.7 -> 6.1Improved
add optimized phase mask in the projector (ablation)FreeCam3D · Simulation test, Table 1Lz (mm): 90.3 -> 6.1Improved
add optimized phase mask in the projector (ablation)FreeCam3D · Simulation test, Table 1Lx (mm): 8.8 -> 8.3Improved
use FreeCam3D instead of Kinect + UNet under camera misalignmentstructured light depth · Camera misalignment (12 cm baseline)Lz_c (mm): 15.7 -> 7.8Improved
use FreeCam3D instead of Kinect + DispNet under camera misalignmentstructured light depth · Camera misalignment (12 cm baseline)Lz_c (mm): 14.8 -> 7.8Improved
use FreeCam3D instead of Kinect + UNet with calibrated fixed camerastructured light depth · Fixed camera (10 cm baseline), calibratedLz_c (mm): 7.8 -> 7.6No clear effect
misalign camera for Kinect + UNet baseline (ablation)Kinect + UNet · Fixed camera vs misalignmentLz_c (mm): 7.8 -> 15.7Hurt
misalign camera for FreeCam3D (ablation)FreeCam3D · Fixed vs misaligned cameraLz_c (mm): 7.6 -> 7.8No clear effect

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy