Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add generative data augmentation (GDA) to raw training | ResNet50 · Cardiomegaly | accuracy: 0.792 -> 0.782 | Hurt |
| add GDA to raw training | DenseNet · Brain tumor | accuracy: 0.742 -> 0.732 | Hurt |
| add GDA to raw training | ResNet50 · Brain tumor | accuracy: 0.783 -> 0.723 | Hurt |
| add FreRec calibration to GDA | ResNet50 · Brain tumor | accuracy: 0.723 -> 0.843 | Improved |
| add FreRec calibration to GDA | ResNet50 · Cardiomegaly | accuracy: 0.782 -> 0.832 | Improved |
| add FreRec calibration to GDA | DenseNet · DR | accuracy: 0.813 -> 0.834 | Improved |
| replace FreRec with DoGE domain adaptation | ViT-B-16 · Cardiomegaly | accuracy: 0.838 vs 0.818 | No clear effect |
| replace FreRec with DoGE domain adaptation | DenseNet · DR | accuracy: 0.834 vs 0.841 | Mixed |
| add RHM after SHR (SHR only vs full FreRec) (ablation) | FreRec · Cardiomegaly | accuracy: 0.79 -> 0.84 | Improved |
| add RHM after SHR (SHR only vs full FreRec) (ablation) | FreRec · Brain tumor | accuracy: 0.73 -> 0.81 | Improved |
| add SHR before RHM (ablation) | FreRec · Cardiomegaly | accuracy: 0.82 -> 0.84 | Improved |
| add FESA to RHM (ablation) | FreRec · Brain tumor | accuracy: 0.75 -> 0.80 | Improved |
Closest papers by meaning
- Fourier-basis Functions to Bridge Augmentation Gap: Rethinking Frequency Augmentation in Image Classification (CVPR 2024 · similarity 0.82)
- Dual Data Alignment Makes AI-Generated Image Detector Easier Generalizable (NeurIPS 2025 · similarity 0.82)
- MMed-RAG: Versatile Multimodal RAG System for Medical Vision Language Models (ICLR 2025 · similarity 0.81)
- AIF-SFDA: Autonomous Information Filter Driven Source-Free Domain Adaptation for Medical Image Segmentation (AAAI 2025 · similarity 0.81)
- Instruct Where the Model Fails: Generative Data Augmentation via Guided Self-contrastive Fine-tuning (AAAI 2025 · similarity 0.81)
- Large-scale and Fine-grained Vision-language Pre-training for Enhanced CT Image Understanding (ICLR 2025 · similarity 0.81)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.