atlas

Research map / Vision-language and multimodal / CLIP and zero-shot

Large-scale and Fine-grained Vision-language Pre-training for Enhanced CT Image Understanding

ICLR 2025 · Vision-language and multimodal › CLIP and zero-shot · approach: Language models for zero-shot reasoning · 2 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Proposes fVLM, a fine-grained CLIP-style pre-training method that aligns anatomy-level CT regions with per-anatomy report descriptions and corrects false negatives via a dual reduction and co-teaching scheme, trained on the 69K-patient MedVL-CT69K dataset.

Problem

Global image-report contrastive pre-training for CT misaligns local anatomical regions with report sentences, and fine-grained anatomy-level alignment suffers from many false negatives among normal and similarly diseased samples.

Approach

Match anatomy segmentation masks to per-anatomy report descriptions and run contrastive learning per anatomy; identify normal anatomies from the impression section and correct contrastive targets using similarity predictions from a co-taught second model.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Use fVLM instead of CLIPZero-shot abnormality detection · MedVL-CT69KAUC: +12.9 pointsHelped
Use fVLM instead of MerlinZero-shot abnormality detection · MedVL-CT69KAUC: +9.4 pointsHelped
Use fVLM instead of CT-CLIPZero-shot abnormality detection · CT-RATE internal evaluationAUC: 7.4%Helped
Use fVLM instead of CT-CLIPZero-shot abnormality detection · Rad-ChestCT external evaluationAUC: 4.8%Helped
Use fVLM instead of CLIPFrozen-encoder report generation · MedVL-CT69KACC: 4.2 pointsHelped
Use fVLM instead of CLIPFrozen-encoder report generation · MedVL-CT69KGREEN: 3.8 pointsHelped
Use fVLM instead of CLIPFine-tuned report generation · MedVL-CT69KACC: 2.5-point improvementHelped
Use fVLM instead of CLIPFine-tuned report generation · MedVL-CT69KGREEN: 2.6-point improvementHelped
Add fine-grained alignment and normal false-negative correction (ablation)fVLM · MedVL-CT69K validationAUC: 7.8 pointsHelped
Add fine-grained alignment and normal false-negative correction (ablation)fVLM · MedVL-CT69K validationACC: 6.0 pointsHelped
Use co-teaching rather than the training model itself for label correction (ablation)fVLM contrastive pre-training · MedVL-CT69Kdiagnostic performanceHelped
Use co-teaching rather than a momentum model for label correction (ablation)fVLM contrastive pre-training · MedVL-CT69Kdiagnostic performanceHelped

Surprising findings

Limitations

Experimental setup

Datasets: MedVL-CT69K CT-RATE Rad-ChestCT

Benchmarks: MedVL-CT69K CT-RATE Rad-ChestCT

Metrics: AUC ACC Spec Sens F1 Prec BLEU-1 BLEU-4 METEOR ROUGE-L

Baselines: CLIP LoVT MGCA Imitate ASG CT-GLIP BIUD Merlin CT-CLIP CT-VocabFine CT-LiPro

Builds on: CLIP MAE BERT TotalSegmentator

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy