Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add LNL block after stage 4 (ablation) | CircleNet · DDH test | average error (pixels): 4.99 -> 4.79 | Improved |
| add LNL block after stage 4 (ablation) | CircleNet · DDH test | FPS: 25.6 -> 22.7 | Hurt |
| use CircleNet radius prediction vs Faster R-CNN+GN+WS | Faster R-CNN · DDH test | average error (pixels): 6.59 -> 4.99 | Improved |
| place LNL after stage 5 instead of stage 4 (ablation) | CircleNet+LNL · DDH test | average error (pixels): 4.79 -> 4.96 | Hurt |
| place LNL after stage 5 instead of stage 4 (ablation) | CircleNet+LNL · DDH test | FPS: 22.7 -> 11.8 | Hurt |
| add non-local (NL) block after stage 4 (ablation) | CircleNet · DDH test | average error (pixels): 4.99 -> 4.95 | No clear effect |
| add GC block after stage 4 (ablation) | CircleNet · DDH test | average error (pixels): 4.99 -> 4.86 | No clear effect |
| radius loss weight lambda_r 0.01 to 0.1 (ablation) | CircleNet+LNL · DDH test | average error (pixels): 4.90 -> 4.79 | Improved |
| vary lambda_r among 0.2, 0.5, 0.7, 1 (ablation) | CircleNet+LNL · DDH test | average error (pixels): 4.79 vs 4.92, 4.82, 4.83, 4.90 | Hurt |
| area ratio mu 20/32 to 24/32 (ablation) | LNL block · DDH test | average error (pixels): 4.84 -> 4.79 | Improved |
| area ratio mu 28/32 instead of 24/32 (ablation) | LNL block · DDH test | average error (pixels): 4.79 -> 4.92 | Hurt |
| Gaussian instead of Embedded Gaussian relation (ablation) | LNL block · DDH test | average error (pixels): 4.79 -> 4.99 | Hurt |
Earlier methods this paper compares with
Named baselines from earlier accepted papers in this paper's results tables: better than 4 of 4 on most shared results.
- Libra R-CNN — Libra R-CNN: Towards Balanced Learning for Object Detection (CVPR 2019) · better on 1 of 1 shared result
- FCOS — FCOS: Fully Convolutional One-Stage Object Detection (ICCV 2019) · better on 1 of 1 shared result
- Cascade R-CNN — Cascade R-CNN: Delving Into High Quality Object Detection (CVPR 2018) · better on 1 of 1 shared result
- Faster R-CNN — Faster R-CNN: Towards Real-Time Object Detection with Region Proposal Networks (TPAMI 2016) · better on 1 of 1 shared result
Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.
Closest papers by meaning
- Contour-Hugging Heatmaps for Landmark Detection (CVPR 2022 · similarity 0.84)
- Window Loss for Bone Fracture Detection and Localization in X-ray Images with Point-based Annotation (AAAI 2021 · similarity 0.84)
- Domain Generalized Medical Landmark Detection via Robust Boundary-Aware Pre-Training (AAAI 2025 · similarity 0.83)
- DPA-P2PNet: Deformable Proposal-Aware P2PNet for Accurate Point-Based Cell Detection (AAAI 2024 · similarity 0.81)
- VISTA3D: A Unified Segmentation Foundation Model For 3D Medical Imaging (CVPR 2025 · similarity 0.80)
- T-FAKE: Synthesizing Thermal Images for Facial Landmarking (CVPR 2025 · similarity 0.80)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.