Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| use Window Loss with point-based supervision instead of image-classification or box-detection baselines | Pelvic X-ray fracture detection · Pelvic X-ray fracture detection | AUROC: 0.974 -> 0.983 | Improved |
| use Window Loss with point-based supervision instead of the strongest baseline | Pelvic X-ray fracture detection · Pelvic X-ray fracture detection | FROC score: 88.1% -> 89.9% | Improved |
| use KLD rather than MSE as the Window Loss divergence | Window Loss · Pelvic X-ray fracture detection | AUROC: 0.979 -> 0.983 | Improved |
| use MSE rather than KLD as the Window Loss divergence | Window Loss · Pelvic X-ray fracture detection | FROC score: 89.6% -> 89.9% | Improved |
| increase rℓ from 50 to 100 (ablation) | WL-MSE · Pelvic X-ray fracture detection | FROC score: 89.9% -> 86.4% | Hurt |
| increase rℓ from 50 to 150 (ablation) | WL-MSE · Pelvic X-ray fracture detection | FROC score: 89.9% -> 82.0% | Hurt |
| reduce τ from 2 to 0.4 (ablation) | WL-MSE · Pelvic X-ray fracture detection | FROC score: 89.9% -> 89.3% | Hurt |
| increase τ from 2 to 5 (ablation) | WL-MSE · Pelvic X-ray fracture detection | FROC score: 89.9% -> 88.2% | Hurt |
| increase τ from 2 to 10 (ablation) | WL-MSE · Pelvic X-ray fracture detection | Recall@0.1 FP/image: 87.4% -> 69.6% | Hurt |
| set ru=rℓ=50 and τ=0, producing binary bounds (ablation) | WL-MSE · Pelvic X-ray fracture detection | FROC score: 89.9% -> 86.1% | Hurt |
| reduce ru from 200 to 50 (ablation) | WL-MSE · Pelvic X-ray fracture detection | FROC score: 89.9% -> 87.2% | Hurt |
| increase rℓ from 50 to 100 (ablation) | WL-KLD · Pelvic X-ray fracture detection | FROC score: 89.6% -> 85.4% | Hurt |
Earlier methods this paper compares with
Named baselines from earlier accepted papers in this paper's results tables: better than 2 of 2 on most shared results.
- FCOS — FCOS: Fully Convolutional One-Stage Object Detection (ICCV 2019) · better on 3 of 3 shared results
- Faster-RCNN — Faster R-CNN: Towards Real-Time Object Detection with Region Proposal Networks (TPAMI 2016) · better on 3 of 3 shared results
Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.
Closest papers by meaning
- OralXrays-9: Towards Hospital-Scale Panoramic X-ray Anomaly Detection via Personalized Multi-Object Query-Aware Mining (CVPR 2025 · similarity 0.83)
- RAM-W600: A Multi-Task Wrist Dataset and Benchmark for Rheumatoid Arthritis (NeurIPS 2025 · similarity 0.81)
- BLS-GAN: A Deep Layer Separation Framework for Eliminating Bone Overlap in Conventional Radiographs (AAAI 2025 · similarity 0.81)
- Mudslide: A Universal Nuclear Instance Segmentation Method (CVPR 2024 · similarity 0.81)
- Novel Class Discovery in Chest X-rays via Paired Images and Text (AAAI 2024 · similarity 0.81)
- Coupled Laplacian Eigenmaps for Locally-Aware 3D Rigid Point Cloud Matching (CVPR 2024 · similarity 0.81)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.