Research map / 3D vision / 3D generation
Prospective Dynamic 3D MRI Reconstruction via Latent-Space Motion Tracking from Single Measurement
Lixuan Chen, Zhongnan Liu, Jesse Hamilton, James M. Balter, Jeong Joon Park, Liyue Shen
Read the paperCheck your idea against 137,217 papers
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| use PDMR instead of MR-MOTUS | prospective reconstruction · In-house (immediate) prospective | PSNR: 41.04 -> 46.32 | Improved |
| use PDMR instead of MR-MOTUS | prospective reconstruction · XCAT Phantom (immediate) prospective | PSNR: 24.39 -> 26.28 | Improved |
| use PDMR instead of MR-MOTUS | prospective reconstruction · XCAT Phantom (after 2 min) prospective | PSNR: 24.22 -> 25.52 | Improved |
| use PDMR instead of MR-MOTUS | prospective reconstruction · In-house (after 2 min) prospective | PSNR: 41.11 -> 43.39 | Improved |
| use PDMR instead of Prior-INR (hand-crafted discrete manifold) | prospective reconstruction · In-house (immediate) prospective | PSNR: 26.72 -> 46.32 | Improved |
| use PDMR instead of SPINER (retrospective INR) | prospective reconstruction · XCAT Phantom (immediate) prospective | SSIM: 0.873 -> 0.958 | Improved |
| delay prospective scan by 2 minutes | PDMR · In-house prospective | PSNR: 46.32 -> 43.39 | Hurt |
| delay prospective scan by 2 minutes | PDMR · XCAT Phantom prospective | PSNR: 26.28 -> 25.52 | Hurt |
| use PDMR instead of MR-MOTUS in retrospective learning | retrospective reconstruction · In-house retrospective | PSNR: 43.50 -> 47.60 | Improved |
| use PDMR instead of SPINER in retrospective learning | retrospective reconstruction · XCAT retrospective | PSNR: 21.26 -> 26.63 | Improved |
| add 1 mm unseen respiratory offset | PDMR · In-house | PSNR: 52.53 -> 44.65 | Hurt |
| add 3 mm unseen respiratory offset | PDMR · In-house | PSNR: 52.53 -> 38.80 | Hurt |
Closest papers by meaning
- Spatiotemporal-Aware Neural Fields for Dynamic CT Reconstruction (AAAI 2025 · similarity 0.86)
- MotionTTT: 2D Test-Time-Training Motion Estimation for 3D Motion Corrected MRI (NeurIPS 2024 · similarity 0.85)
- Towards Prospective Medical Image Reconstruction via Knowledge-Informed Dynamic Optimal Transport (NeurIPS 2025 · similarity 0.85)
- Bidirectional Recurrence for Cardiac Motion Tracking with Gaussian Process Latent Coding (NeurIPS 2024 · similarity 0.84)
- ReMatching Dynamic Reconstruction Flow (ICLR 2025 · similarity 0.84)
- Fully Convolutional Slice-to-Volume Reconstruction for Single-Stack MRI (CVPR 2024 · similarity 0.83)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.