Proposes a fully convolutional Splat–Slice U-Net that predicts slice motion from a single MRI slice stack, using splatting/slicing and a rigid motion-compensating loss, with a U-Net interpolator to fill holes in the reconstruction.
Problem
Slice-to-volume reconstruction (SVR) of motion-corrupted 2D MRI slice stacks normally needs multiple orthogonal stacks, lengthening scans and limiting use in time-sensitive settings such as fetal fMRI.
Approach
Formulate SVR as supervised single-stack motion estimation: a 3D FCN (Splat–Slice U-Net) interprets classical SVR's slice/splat operations to predict per-slice dense motion fields, with the 3D volume obtained by splatting slices using the predicted motion, plus a rigid motion-compensated MSE loss and a separate U-Net interpolator.
Key results
- Single-stack motion prediction error of 1.81 mm APE/EPE versus 3.27 mm for SVoRT (v2) and 8.08 mm for SVRnet, a 77.6% and 44.6% reduction relative to SVRnet and SVoRT respectively.
- Volume PSNR of 23.43 dB versus 18.49 dB for SVoRT (v2) and 16.03 dB for SVRnet on fetal validation.
- Inference takes 0.224 s per stack, versus 0.011 s for SVRnet and 0.142 s for SVoRT (v2).
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| Use the proposed single-stack FCN instead of SVoRT (v2) | Fetal brain SVR · Fetal brain validation, 1 stack | Motion EPE (mm): 3.27±0.71 -> 1.81±0.40 | Helped |
| Use the proposed single-stack FCN instead of SVoRT (v2) | Fetal brain SVR · Fetal brain validation, 1 stack | Slice PSNR (dB): 20.77±1.28 -> 23.69±1.39 | Helped |
| Use the proposed single-stack FCN instead of SVoRT (v2) | Fetal brain SVR · Fetal brain validation, 1 stack | Volume PSNR (dB): 18.49±1.63 -> 23.43±1.40 | Helped |
| Use the proposed single-stack FCN instead of SVoRT (v2) | Fetal brain SVR · Fetal brain validation, 1 stack | Time (sec): 0.142s -> 0.224s | Hurt |
| Compensate for global rigid motion in the training loss (ablation) | Splat–Slice U-Net motion prediction · Adult brain validation | Motion prediction accuracy | Helped |
| Compensate for translations only instead of global rigid motion (ablation) | Splat–Slice U-Net motion prediction · Adult brain validation | Motion prediction accuracy | Hurt |
| Use ordinary MSE loss without motion compensation (ablation) | Splat–Slice U-Net motion prediction · Adult brain validation | Motion prediction accuracy | Hurt |
| Train separate models for different slice directions (ablation) | Splat–Slice U-Net · Adult brain validation, sagittal versus axial stacks | Motion MSE (voxels): 0.89 (MSE) -> 1.33 (MSE) | Mixed |
Surprising findings
- The SVRnet baseline is slower but its runtime (0.011 s) is faster than the proposed method (0.224 s); the proposed method trades a little speed for accuracy.
Limitations
- Fetal SVR network trained on automatically segmented brain slices, not raw unsegmented stacks.
- Only rigid motion is handled; deformable motion (e.g., fetal torso, placenta) is future work.
- Reconstruction can contain holes requiring a separate interpolation network.
Experimental setup
Datasets: ABIDE ADHD200 COBRE GSP MCIC OASIS PPMI UKB Buckner39 CRL Fetal Atlases FeTA MIAL
Benchmarks: FeTA (validation, synthetic slicing) MIAL real fetal acquisitions adult brain synthetic slicing
Metrics: motion MSE end-point error (EPE) slice PSNR volume PSNR APE runtime
Baselines: SVRnet SVoRT (v2) PlaneInVol
Builds on: U-Net Rousseau et al. slice-to-volume reconstruction monocular disparity estimation SVoRT SVRnet
Closest papers by meaning
- SVRMamba: Slice-to-Volume Reconstruction from Multiple MRI Stacks with Slice Sequence Guided Mamba (AAAI 2025 · similarity 0.91)
- D2SA: Dual-Stage Distribution and Slice Adaptation for Efficient Test-Time Adaptation in MRI Reconstruction (NeurIPS 2025 · similarity 0.86)
- LiFT: Lifted Inter-slice Feature Trajectories for 3D Image Generation from 2D Generators (NeurIPS 2026 · similarity 0.85)
- Null Space Matters: Range-Null Decomposition for Consistent Multi-Contrast MRI Reconstruction (AAAI 2024 · similarity 0.85)
- Boosting ViT-based MRI Reconstruction from the Perspectives of Frequency Modulation, Spatial Purification, and Scale Diversification (AAAI 2025 · similarity 0.85)
- Progressive Divide-and-Conquer via Subsampling Decomposition for Accelerated MRI (CVPR 2024 · similarity 0.85)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.