Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add reconstruction loss via k2 (ablation) | uncalibrated dual-band optimization · Simulation, SNR sweep | temperature error reduction: 90.10% error reduction | Improved |
| add second-order smoothing loss (ablation) | uncalibrated dual-band optimization · Simulation, SNR sweep | temperature error reduction: 56.73% error reduction | Improved |
| add normalized Huber loss (ablation) | uncalibrated dual-band optimization · Simulation, SNR sweep | temperature error reduction: 11.31% error reduction | Improved |
| add explicit noise modeling terms (ablation) | uncalibrated dual-band optimization · Simulation, SNR sweep | temperature error reduction: 11.64% error reduction | Improved |
| use uncalibrated method instead of naive least squares | wineglass video · Wineglass video temperature | estimation error (%): 31.68% -> 1.72% | Improved |
| use uncalibrated method instead of BCP | coffee pot video · Coffee pot video temperature | estimation error (%): 6.62% -> 5.34% | Improved |
| use calibrated emissivity instead of uncalibrated estimation | dual-band separation · Wineglass versus coffee pot | estimation error (%): wineglass 1.72% -> 5.04%; coffee pot 5.34% -> 0.36% | Mixed |
| use spectral-library calibration instead of reflector method for low-emissivity materials | emissivity calibration · Chrome ball emissivity | emissivity (reference 0.1): 0.43 -> 0.12 | Improved |
| use calibration method instead of reflector method for high-emissivity materials | emissivity calibration · Blue paint, glass jar, wineglass | emissivity: blue paint 0.88 vs 0.88 | No clear effect |
| limit to scenes where background is uncorrelated with object signal | dual-band method · uniformly warming room | validity | Hurt |
Closest papers by meaning
- Time-Resolved Light Transport Decomposition for Thermal Photometric Stereo (CVPR 2018 · similarity 0.87)
- Time-Resolved Far Infrared Light Transport Decomposition for Thermal Photometric Stereo (TPAMI 2019 · similarity 0.87)
- PhysIR-Splat: Physically Consistent Thermal Infrared Radiative Transfer in 3D Gaussian Splatting (CVPR 2026 · similarity 0.86)
- A Theory of Joint Light and Heat Transport for Lambertian Scenes (CVPR 2024 · similarity 0.85)
- ThermalGaussian: Thermal 3D Gaussian Splatting (ICLR 2025 · similarity 0.85)
- NTR-Gaussian: Nighttime Dynamic Thermal Reconstruction with 4D Gaussian Splatting Based on Thermodynamics (CVPR 2025 · similarity 0.85)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.