AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Proposes an INR-based per-subject compressor for 4D fMRI that models ICA-initialized reusable neuronal activation patterns and their spatial distributions with INR networks and a feature fusion block, outperforming H.264/H.265/JPEG/NeRF/SIREN/HNeRV/SSF/DVC at ~100x compression.

Problem

Compressing massive 4D fMRI data is hard due to complex temporal dynamics, low SNR, and redundancies within and between brain regions that frame-adjacent video codecs and INR video compressors do not exploit.

Approach

Model fMRI as a weighted superposition of K learnable reusable activation patterns (a learnable matrix initialized by ICA), with INR MLPs predicting each pattern's spatial distribution from coordinates, followed by a feature fusion network, rather than directly fitting coordinates-to-signal mappings.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add the Feature Fusion Block (ablation)ICAINR · fMRI ablation studyPSNR (dB): 78.67 -> 78.74Helped
initialize activation patterns with ICA instead of uniform initialization (ablation)ICAINR · fMRI ablation studyFLA Residual: 0.36$\pm$0.30 -> 0.32$\pm$0.24Helped
initialize activation patterns with ICA instead of normal initialization (ablation)ICAINR · fMRI ablation studyFLA Residual: 0.49$\pm$0.35 -> 0.32$\pm$0.24Helped
decompose fMRI signals into neuronal activation patterns rather than directly model the 4D data with INR (ablation)ICAINR · fMRI ablation studyPSNR (dB): 72.93 -> 78.67Helped
use ICAINR rather than existing compressors at similar compression ratiosfMRI · fMRI (≈100× compression)PSNR (dB): 70.49 -> 79.31Helped

Surprising findings

Limitations

Experimental setup

Datasets: OpenfMRI ds000007 OpenfMRI ds000101 OpenfMRI ds000102 Haxby

Benchmarks: OpenfMRI ds000007 OpenfMRI ds000101 OpenfMRI ds000102 Haxby

Metrics: PSNR SSIM compression ratio FLA residual mean/std FCA residual mean/std 10-fold classification accuracy AUC

Baselines: JPEG H.264 H.265 SSF DVC NeRF HNeRV SIREN