atlas

Research map / Label-efficient and robust learning / Self-supervised and contrastive

Learning Low-Rank Feature for Thorax Disease Classification

NeurIPS 2024 · Label-efficient and robust learning › Self-supervised and contrastive · approach: Self-supervised neuroimaging representations · 3 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Proposes Low-Rank Feature Learning (LRFL), which adds a separable approximation of the truncated nuclear norm to fine-tuning of MAE-pretrained CNNs/ViTs for thorax disease classification, reporting new mAUC records on NIH ChestX-ray14 and CheXpert and accuracy on COVIDx.

Problem

Thorax disease classification on chest radiographs is hampered by noise and non-disease background in features; existing SSL-pretrained CNN/ViT pipelines lack principled ways to suppress these high-frequency, non-informative components.

Approach

Add a truncated nuclear norm penalty on the feature matrix (approximated by a separable form using eigenvectors refreshed every t0 epochs) to the classifier/fine-tuning loss so that features are low-rank, backed by a generalization bound showing the benefit of a small truncated nuclear norm.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Apply LRFL to ViT-BViT-B · NIH ChestX-ray14mAUC: 83.00 -> 83.40Helped
Apply LRFL to ViT-BViT-B · COVIDxaccuracy: 95.3 -> 97.0Helped
Apply LRFL to ViT-BViT-B · COVIDxCOVID-19 sensitivity: 95.5 -> 98.5Helped
Apply LRFL to ViT-BViT-B · CheXpertmAUC: 89.3 -> 89.8Helped
Replace LRFL with mix-up (ablation)ViT-S and ViT-B · NIH ChestX-ray14mAUC: 82.27 -> 82.09; 83.00 -> 82.37Hurt
Replace LRFL with label smoothing (ablation)ViT-S and ViT-B · NIH ChestX-ray14mAUC: 82.27 -> 82.24; 83.00 -> 82.99Mixed
Replace LRFL with EMA (ablation)ViT-S and ViT-B · NIH ChestX-ray14mAUC: 82.27 -> 82.26; 83.00 -> 82.98Mixed
Vary rank T from 0.01r to 0.3r (ablation)ViT-B-LR · NIH ChestX-ray14mAUC: higher than 83% for most values for TNo clear effect

Surprising findings

Limitations

Experimental setup

Datasets: ImageNet-1k X-rays (0.3M/0.5M) NIH ChestX-ray14 COVIDx CheXpert

Benchmarks: NIH ChestX-ray14 COVIDx CheXpert

Metrics: mAUC top-1 accuracy Covid-19 sensitivity

Baselines: MAE ViT-B/16 MAE ViT-S/16 MoCo v2 DenseNet-121 COVIDNet-CXR Mix-up Label Smoothing EMA

Builds on: masked autoencoders Vision Transformer truncated nuclear norm

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy