atlas

Research map / Large language models / Agents, code and math

MedRAX: Medical Reasoning Agent for Chest X-ray

ICML 2025 · Large language models › Agents, code and math · approach: LLM-driven embodied and driving agents · 2 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Introduces MedRAX, a training-free ReAct agent that orchestrates CXR analysis tools and a multimodal LLM (GPT-4o), plus ChestAgentBench, a 2,500-question six-choice benchmark built from Eurorad cases.

Problem

Chest X-ray interpretation tools operate in isolation and existing medical VQA benchmarks test only simple single-step reasoning, so complex multi-step CXR reasoning is poorly served and poorly evaluated.

Approach

A LLM-driven ReAct agent that dynamically calls a toolbox of specialized CXR models (VQA, segmentation, grounding, report generation, classification, generation) without any additional training, paired with a new GPT-4o-generated six-choice benchmark from expert-curated Eurorad cases.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Use MedRAX's tool-orchestrated agent instead of the strongest listed baselineCXR interpretation models · ChestAgentBench — Overallaccuracy: 57.9 -> 63.1Helped
Use MedRAX's tool-orchestrated agent instead of the strongest listed baselineCXR interpretation models · CheXbench — Overallaccuracy: 64.7 -> 68.1Helped
Use MedRAX's tool-orchestrated agent instead of GPT-4oCXR VQA models · CheXbench — Rad-Restructaccuracy: 53.9 -> 68.7Helped
Use MedRAX's tool-orchestrated agent instead of GPT-4oCXR VQA models · CheXbench — SLAKEaccuracy: 85.4 -> 82.9Hurt
Use MedRAX's tool-orchestrated agent instead of CheXagentCXR image-text reasoning models · CheXbench — Fine-Grained Reasoningaccuracy: 59.0 -> 52.6Hurt
Use MedRAX instead of M4CXRradiology report-generation models · MIMIC-CXR testmF1-14: 60.6 -> 79.1Helped
Use MedRAX instead of M4CXRradiology report-generation models · MIMIC-CXR testmF1-5: 61.8 -> 64.9Helped
Use MedRAX instead of M4CXRradiology report-generation models · MIMIC-CXR testMF1-14: 40.0 -> 34.2Hurt
Use MedRAX instead of Med-PaLM M 84Bradiology report-generation models · MIMIC-CXR testMF1-5: 51.6 -> 48.2Hurt
Use MedRAX instead of M4CXRmedical VQA models · SLAKE chest X-ray VQAaccuracy: 85.1 -> 90.35Helped
Use MedRAX instead of M4CXRmedical VQA models · SLAKE chest X-ray VQArecall: 86.0 -> 91.23Helped

Surprising findings

Limitations

Experimental setup

Datasets: Eurorad chest imaging cases CheXbench (Rad-Restruct, SLAKE, OpenI) MIMIC-CXR CheXpert Plus ChestX-Det SLAKE

Benchmarks: ChestAgentBench CheXbench MIMIC-CXR report generation SLAKE VQA

Metrics: accuracy micro F1 (mF1-14, mF1-5) macro F1 (MF1-14, MF1-5) recall

Baselines: LLaVA-Med CheXagent Llama-3.2-90B Vision GPT-4o RadFM MAIRA-1 LLaVA-Rad Med-PaLM M 84B M4CXR

Builds on: ReAct LangGraph LLaVA-Med CheXagent M4CXR

Closest papers by meaning