Research map / Video / Video segmentation and tracking
Learning Motion-Robust Remote Photoplethysmography through Arbitrary Resolution Videos
Jianwei Li, Zitong Yu, Jingang Shi
Read the paperCheck your idea against 137,217 papers
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| Add PFE and TFA to PhysNet | PhysNet · UBFC-rPPG | MAE (bpm): 2.95 -> 0.76 | Improved |
| Add PFE and TFA to PhysNet | PhysNet · PURE | MAE (bpm): 2.16 -> 1.44 | Improved |
| Add PFE and TFA to PhysNet | PhysNet · PURE | RMSE (bpm): 2.7 -> 2.50 | Hurt |
| Add PFE and TFA to PhysNet | PhysNet · COHFACE | RMSE (bpm): 10.76 -> 3.92 | Improved |
| Add PFE to PhysNet | PhysNet · UCLA-rPPG | MAE (bpm): 11.82 -> 9.15 | Improved |
| Add PFE and TFA to PhysNet | PhysNet · UCLA-rPPG | MAE (bpm): 11.82 -> 8.73 | Improved |
| Add PFE and TFA to PhysFormer | PhysFormer · UCLA-rPPG | MAE (bpm): 11.75 -> 5.96 | Improved |
| Add PFE and TFA | PhysNet · UBFC-rPPG, varying face resolution | MAE (bpm): 10.73 -> 1.86; 8.14 -> 1.97; 11.85 -> 1.85; 7.15 -> 1.88 | Improved |
| Add RAE to PFE (ablation) | PFE · UBFC-rPPG, fixed resolution 64×64 | MAE (bpm): 3.76 -> 2.33 | Improved |
| Add the cross-resolution constraint to PFE (ablation) | PFE · UBFC-rPPG, fixed resolution 64×64 | MAE (bpm): 2.84 -> 2.33 | Improved |
| Add TFA without PFE (ablation) | PhysNet · UBFC-rPPG, fixed resolution 64×64 | MAE (bpm): 6.82 -> 8.29 | Hurt |
| Use bidirectional instead of single-direction TFA (ablation) | PFE · UBFC-rPPG, fixed resolution 64×64 | MAE (bpm): 2.44 -> 1.63 | Improved |
Closest papers by meaning
- Facial Video-based Remote Physiological Measurement via Self-supervised Learning (TPAMI 2023 · similarity 0.93)
- Remote Photoplethysmography in Real-World and Extreme Lighting Scenarios (CVPR 2025 · similarity 0.93)
- PhysFormer: Facial Video-Based Physiological Measurement With Temporal Difference Transformer (CVPR 2022 · similarity 0.93)
- RhythmMamba: Fast, Lightweight, and Accurate Remote Physiological Measurement (AAAI 2025 · similarity 0.91)
- PhysDiff: Physiology-based Dynamicity Disentangled Diffusion Model for Remote Physiological Measurement (AAAI 2025 · similarity 0.90)
- FacePhys: State of the Heart Learning (NeurIPS 2026 · similarity 0.89)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.