atlas

Research map / Vision-language and multimodal / Multimodal LLMs

VILA-M3: Enhancing Vision-Language Models with Medical Expert Knowledge

CVPR 2025 · Vision-language and multimodal › Multimodal LLMs · approach: VLM capability analysis · 29 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Proposes VILA-M3, a medical VLM that learns to trigger domain expert models (VISTA3D, BRATS, TorchXRayVision) and incorporates their feedback via an extra expert-guided instruction fine-tuning stage.

Problem

General-purpose and existing medical VLMs lack the fine-grained precision needed for clinical tasks such as segmentation, classification, report generation and VQA, and are evaluated on static datasets with unreliable LLM judges.

Approach

Adds a fourth training stage, expert-guided instruction fine-tuning, where the VLM learns to emit keyword/argument triggers for on-demand expert segmentation and classification models and consumes their outputs as feedback in the conversation, combined with a balanced medical data mixture.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add expert-model feedback to VILA-M3-3B (ablation)VILA-M3-3B · ChestX-ray14 classificationF1: 48.4 -> 51.3Helped
add expert-model feedback to VILA-M3-13B (ablation)VILA-M3-13B · CheXpert classificationF1: 55.8 -> 61.5Helped
add expert-model feedback to VILA-M3-3B (ablation)VILA-M3-3B · MIMIC-CXR report generationROUGE: 31.4 -> 31.7Helped
add expert-model feedback to VILA-M3-8B (ablation)VILA-M3-8B · MIMIC-CXR report generationBLEU-4: 21.4 -> 21.2Hurt
add expert-model feedback to VILA-M3-40B (ablation)VILA-M3-40B · MIMIC-CXR report generationBLEU-4: 21.6 -> 21.6No clear effect
balance the healthcare training data (ablation)VILA-M3 · medical benchmark metricsaverage across metrics: ~4%Helped
train VILA-M3 for 3 epochs instead of 1 or 2 (ablation)VILA-M3 model variants · medical benchmarksperformanceHurt
fine-tune VILA-1.5 as VILA-M3 with expert-guided IFTVILA-M3 · traditional VLM benchmarks averageaverage: 75.5 -> 52.2Hurt

Surprising findings

Limitations

Experimental setup

Datasets: SLAKE PathVQA RadVQA MIMIC-CXR MIMIC-Diff-VQA ChestX-ray14 CheXpert BRATS 2018 MSD TotalSegmentatorV2 USMLE

Benchmarks: RadVQA MIMIC-VQA SLAKE PathVQA MIMIC-CXR report generation ChestX-ray14 CheXpert VQAv2 GQA VizWiz SQA-I VQA-T

Metrics: accuracy F1 BLEU-4 ROUGE GREEN

Baselines: Med-Gemini GPT-4o Llava-Med Llava-Rad DCL TorchXRayVision VILA1.5

Builds on: VILA LLaVA Vicuna Llama-3 Yi

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy