Research map / 3D vision / Depth and stereo
Blur Aware Calibration of Multi-Focus Plenoptic Camera
Mathieu Labussiere, Celine Teuliere, Frederic Bernardin, Omar Ait-Aider
Check your idea against 137,217 papers
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| Use blur-aware calibration instead of RxLive | Raytrix R12 camera calibration · All datasets | relative translation error (%): 6,803333333 -> 3.33 | Improved |
| Use blur-aware calibration instead of baseline [cite] | Raytrix R12 camera calibration · All datasets | relative translation error (%): 3,563333333 -> 3.33 | Improved |
| Use blur-aware calibration instead of baseline [cite] | Raytrix R12 camera calibration · R12-A | relative translation error (%): 6.834 -> 3.731 | Improved |
| Use blur-aware calibration instead of baseline [cite] | Raytrix R12 camera calibration · R12-B | relative translation error (%): 1.155 -> 3.31682 | Hurt |
| Use blur-aware calibration instead of baseline [cite] | Raytrix R12 camera calibration · R12-C | relative translation error (%): 2.69739 -> 2.95057 | Hurt |
| Use blur-aware calibration instead of RxLive | Raytrix R12 camera calibration · R12-A | relative translation error (%): 4.63289 -> 3.731 | Improved |
| Use blur-aware calibration instead of RxLive | Raytrix R12 camera calibration · R12-B | relative translation error (%): 4.25715 -> 3.31682 | Improved |
| Use blur-aware calibration instead of RxLive | Raytrix R12 camera calibration · R12-C | relative translation error (%): 11.5188 -> 2.95057 | Improved |
| Add blur radius to raw-image reprojection features | Blur-aware calibration · R12-A, R12-B, R12-C | blur-radius reprojection RMSE | Improved |
Closest papers by meaning
- Leveraging Blur Information for Plenoptic Camera Calibration (IJCV 2022 · similarity 0.95)
- Corner-Based Geometric Calibration of Multi-Focus Plenoptic Cameras (ICCV 2017 · similarity 0.90)
- Baseline and Triangulation Geometry in a Standard Plenoptic Camera (IJCV 2017 · similarity 0.83)
- Geometric Calibration of Micro-Lens-Based Light Field Cameras Using Line Features (TPAMI 2016 · similarity 0.83)
- Principals and Pupils of Lenslet-Based Light Field Camera Calibration (TPAMI 2026 · similarity 0.82)
- A Physics-Informed Blur Learning Framework for Imaging Systems (CVPR 2025 · similarity 0.81)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.