AI Paper Atlas

Research map / 3D vision / Depth and stereo

Corner-Based Geometric Calibration of Multi-Focus Plenoptic Cameras

Sotiris Nousias, Francois Chadebecq, Jonas Pichat, Pearse Keane, Sebastien Ourselin, Christos Bergeles

ICCV 2017 · 3D vision › Depth and stereo · approach: Camera model and calibration for SfM · 29 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
use the proposed saddle-line corner detector instead of Harrismicro-image corner detection · Micro-image corner detection (5014 annotated micro-images)mean corner error (pixels): 3.14 -> 1.16Improved
use the proposed corner detector instead of FASTmicro-image corner detection · Micro-image corner detection (5014 annotated micro-images)mean corner error (pixels): 6.19 -> 1.16Improved
use the proposed corner detector instead of Hough-lines intersectionmicro-image corner detection · Micro-image corner detection (5014 annotated micro-images)corners detected: 3783 -> 3187Improved
perturb detector parameters by up to 20% (ablation)proposed corner detector · Micro-image corner detection (5014 annotated micro-images)mean corner error (pixels): up to 0.283 pixelsNo clear effect
compute focus score on a region around the corner instead of the whole micro-image (ablation)micro-lens classification · Micro-lens type classification (330 clusters of 19 micro-lenses)classification accuracyImproved
use gradient focus measures (Tenenbaum) instead of decomposition measures (ablation)micro-lens classification · Micro-lens type classification (330 clusters of 19 micro-lenses)classification accuracyImproved
classify micro-lens types before calibration of Bok et al. (ablation)Bok et al. calibration · Raytrix R8 calibrationconvergenceImproved
use proposed calibration instead of Bok et al. on extrinsics across micro-lens typescalibration · Extrinsic consistency across micro-lens types (max over 7 poses)max translation difference (mm): 32.1 -> 5.9Improved
use proposed calibration instead of Bok et al. on rotation consistencycalibration · Extrinsic consistency across micro-lens types (max over 7 poses)max rotation difference (deg): 2.5 -> 0.2Improved
use proposed calibration instead of Bok et al. for principal pointcalibration · Raytrix R8 intrinsics, 8 mm checkerboard (principal point cy, pixels)cy (pixels): 1703.58 -> 1080.14Improved
increase number of calibration images from 1 to 6-8 (ablation)proposed calibration · Free-hand calibration (4 mm checkerboard, 10 images)parameter standard deviationImproved

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy