Research map / 3D vision / Depth and stereo
Baseline and Triangulation Geometry in a Standard Plenoptic Camera
Christopher Hahne, Amar Aggoun, Vladan Velisavljević, Susanne Fiebig, Matthias Pesch
Read the paperCheck your idea against 137,217 papers
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| place virtual cameras at the entrance pupil instead of the focal plane | plenoptic triangulation model · real-object baseline B4/B8, infinity focus | baseline deviation (%): -367.2090 -> 0.0000 | Improved |
| place virtual cameras at the entrance pupil instead of the focal plane | plenoptic triangulation model · real-object tilt angle, 4 m focus | tilt angle deviation (%): 899.3410 -> 0.0000 | Improved |
| use a shorter micro lens focal length (MLA I, 1.25 mm vs MLA II, 2.75 mm) | SPC simulation · optical simulation, infinity focus | baseline B6 (mm): 3.7956 -> 8.3503 | Improved |
| use a shorter micro lens focal length | prediction accuracy of model · optical simulation, infinity focus | baseline error (%): 0.0184 -> 0.0635 | Hurt |
| use larger main lens focal length (f90 to f193) | SPC simulation · optical simulation, infinity focus, MLA II | baseline B6 (mm): 1.7752 -> 3.7956 | Improved |
| decrease focusing distance (infinity to 1.5 m) | SPC simulation · optical simulation, f193 + MLA II | baseline B6 (mm): 3.7956 -> 4.9097 | Improved |
| decrease focusing distance (infinity to 1.5 m) | SPC simulation · optical simulation, f193 + MLA II | tilt angle (deg): 0.0000 -> -0.1897 | Improved |
| use shorter main lens (f90) than f193 | prediction accuracy of model · optical simulation, 1.5 m focus, MLA II | entrance pupil position error (%): 0.2157 -> 0.9020 | Hurt |
| use larger main lens focal length f_U | SPC depth sampling · optical simulation Table 7 | depth sampling density | Improved |
Closest papers by meaning
- Corner-Based Geometric Calibration of Multi-Focus Plenoptic Cameras (ICCV 2017 · similarity 0.88)
- Fast Light-Weight Near-Field Photometric Stereo (CVPR 2022 · similarity 0.86)
- Structure-from-motion in micro-image domain for uncalibrated plenoptic 2.0 cameras (IJCV 2026 · similarity 0.86)
- Shape Estimation from Shading, Defocus, and Correspondence Using Light-Field Angular Coherence (TPAMI 2016 · similarity 0.86)
- Ray Space Features for Plenoptic Structure-From-Motion (ICCV 2017 · similarity 0.86)
- Principals and Pupils of Lenslet-Based Light Field Camera Calibration (TPAMI 2026 · similarity 0.86)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
