Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| supervise the content model with serialized RadGraph instead of the full report (ablation) | image-to-text transformer · MIMIC-CXR test | RadGraph F1: 0.186 -> 0.221 | Improved |
| two-step pipeline (serialization + LLM, zero-shot) instead of direct image-to-report | baseline image-to-report model · MIMIC-CXR end-to-end | RadCliQ: 3.553 -> 3.527 | Improved |
| two-step pipeline instead of direct image-to-report | baseline image-to-report model · MIMIC-CXR end-to-end | RadGraph F1: 0.186 -> 0.228 | Improved |
| two-step pipeline instead of direct image-to-report | baseline image-to-report model · MIMIC-CXR end-to-end | CheXbert similarity: 0.352 -> 0.394 | Improved |
| two-step pipeline instead of direct image-to-report | baseline image-to-report model · MIMIC-CXR end-to-end | BLEU-2: 0.184 -> 0.162 | Hurt |
| two-step pipeline instead of direct image-to-report | baseline image-to-report model · MIMIC-CXR end-to-end | BERT Score: 0.378 -> 0.333 | Hurt |
| add in-context style examples (0 to 10) (ablation) | style generation step · MIMIC-CXR end-to-end | RadCliQ: 3.527 -> 3.485 | Improved |
| add in-context style examples (0 to 10) (ablation) | style generation step · MIMIC-CXR end-to-end | BLEU-2: 0.162 -> 0.180 | Improved |
| add in-context style examples (0 to 10) (ablation) | style generation step · MIMIC-CXR end-to-end | RadGraph F1: 0.228 -> 0.224 | No clear effect |
| add in-context style examples (0 to 10) (ablation) | style generation step · Serialization to report (ground-truth input) | RadCliQ: 1.357 -> 1.107 | Improved |
| add in-context style examples (0 to 10) (ablation) | style generation step · Serialization to report (ground-truth input) | BLEU-2: 0.388 -> 0.466 | Improved |
| add in-context style examples (0 to 10) (ablation) | style generation step · Serialization to report (ground-truth input) | BERT Score: 0.568 -> 0.657 | Improved |
Closest papers by meaning
- Divide and Conquer Radiology Report Generation via Observation Level Fine-grained Pretraining and Prompt Tuning (EMNLP 2024 · similarity 0.90)
- Improving the Factual Correctness of Radiology Report Generation with Semantic Rewards (EMNLP 2022 · similarity 0.90)
- LLM-RG4: Flexible and Factual Radiology Report Generation Across Diverse Input Contexts (AAAI 2025 · similarity 0.89)
- Bootstrapping Large Language Models for Radiology Report Generation (AAAI 2024 · similarity 0.89)
- Image-aware Evaluation of Generated Medical Reports (NeurIPS 2024 · similarity 0.88)
- AHIVE: Anatomy-aware Hierarchical Vision Encoding for Interactive Radiology Report Retrieval (CVPR 2024 · similarity 0.87)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.