Research map / Vision-language and multimodal / Multimodal LLMs
BiMediX2 : Bio-Medical EXpert LMM for Diverse Medical Modalities
Sahal Shaji Mullappilly, Mohammed Irfan Kurpath, Sara Pieri, Saeed Yahya Alseiari, Shanavas Cholakkal, Khaled Aldahmani, Fahad Khan, Rao Anwer, Salman Khan, Timothy Baldwin, Hisham Cholakkal
Mohamed bin Zayed University of Artificial Intelligence · Sheikh Shakhbout Medical City · Govt Medical College Kozhikode · Shaikh Tahnoon bin Mohammed Medical City · Tawam Hospital · Linköping University
Read the paperPlace an idea next to itCheck your own paper ↗
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| Add Stage-1 medical concept alignment (projector only) (ablation) | BiMediX2 8B baseline · BiMed-MBench | overall score: 34.9 -> 47.6 | Improved |
| Add Stage-2 LoRA instruction tuning on BiMed-V (ablation) | BiMediX2 8B after Stage-1 · BiMed-MBench | overall score: 47.6 -> 62.2 | Improved |
| Stage-1 projector-only training (ablation) | BiMediX2 8B baseline · Clinical LLM Eval | average accuracy: 67.6 -> 67.6 | No clear effect |
| Add Stage-2 LoRA fine-tuning (ablation) | BiMediX2 8B after Stage-1 · Clinical LLM Eval | average accuracy: 67.6 -> 70.4 | Improved |
| Cascade Google/Bing/Alibaba translation on English model instead of bilingual training (ablation) | BiMediX2-8B ENG · BiMed-MBench (Arabic) | score: 44.61 -> 44.92 / 45.05 / 45.33 (vs 50.47 bilingual) | Improved |
| Use bilingual instruction tuning instead of English model (ablation) | BiMediX2 8B · BiMed-MBench (Arabic) | score: 44.61 -> 50.47 | Improved |
| Scale BiMediX2 from 8B to 70B | BiMediX2 · Clinical LLM benchmarks | average accuracy: 70.4 -> 84.6 | Improved |
| Compare BiMediX2 8B with MAIRA-2 on report generation | BiMediX2 8B · MIMIC-CXR report generation | average score: 0.235 vs 0.283 (MAIRA-2) | Hurt |
| Compare BiMediX2 8B with MiniGPT-Med on Rad-VQA | BiMediX2 8B · Rad-VQA | closed Q accuracy: 0.725 vs 0.829 (MiniGPT-Med) | Hurt |
| Use BiMediX2 70B vs GPT-4 on UPHILL OpenQA | BiMediX2 70B · UPHILL OpenQA | factual accuracy: 51.5% -> 60.6% | Improved |
Earlier methods this paper compares with
Named baselines from earlier accepted papers in this paper's results tables: better than 1 of 1 on most shared results.
- Apollo-72B — APoLLo : Unified Adapter and Prompt Learning for Vision Language Models (EMNLP 2023) · better on 1 of 1 shared result
Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.
Closest papers by meaning
- Interpretable Bilingual Multimodal Large Language Model for Diverse Biomedical Tasks (ICLR 2025 · similarity 0.86)
- SMMILE: An expert-driven benchmark for multimodal medical in-context learning (NeurIPS 2025 · similarity 0.85)
- MediConfusion: Can you trust your AI radiologist? Probing the reliability of multimodal medical foundation models (ICLR 2025 · similarity 0.85)
- Towards a Multimodal Large Language Model with Pixel-Level Insight for Biomedicine (AAAI 2025 · similarity 0.85)
- OmniMedVQA: A New Large-Scale Comprehensive Evaluation Benchmark for Medical LVLM (CVPR 2024 · similarity 0.85)
- MMed-RAG: Versatile Multimodal RAG System for Medical Vision Language Models (ICLR 2025 · similarity 0.85)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
