AI Paper Atlas

Research map / Large language models / Language, safety and interpretability

Structuring Radiology Reports: Challenging LLMs with Lightweight Models

Johannes Moll, Louisa Fay, Asfandyar Azhar, Sophie Ostmeier, Tim Lueth, Sergios Gatidis, Curtis P. Langlotz, Jean-Benoit Delbrouck

EMNLP 2025Large language models › Language, safety and interpretabilityapproach: Data and evaluation methodology8 citations (OpenAlex)

Stanford University · Carnegie Mellon University · Technical University of Munich

Read the paperPlace an idea next to itCheck your own paper ↗

14measured effects
5improved
3no clear effect
5hurt
1mixed

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
LoRA finetuning instead of prefix prompting (ablation)LLMs (mean of five, 3-8B) · FindingsF1-SRR-BERT: 19.7 -> 66.5Improved
add 2-shot ICL to prefix prompting alone (ablation)LLMs (mean of five) · FindingsF1-SRR-BERT: 19.7 -> 23.8Improved
2-shot ICL instead of prefix prompting (ablation)LLMs (mean of five) · ImpressionGREEN / F1-SRR-BERT: GREEN 66.1 -> 72.4; F1-SRR-BERT 78.4 -> 77.6Mixed
combine prefix with ICL (ablation)LLMs (mean of five) · ImpressionF1-SRR-BERT: 78.4 -> 75.2Hurt
use lightweight BERT2BERT instead of LoRA-finetuned LLaMA-3-70BBERT2BERT · structured reports (avg)F1-SRR-BERT: 75.2 -> 79.1Improved
scale LoRA LLaMA-3 from 3B to 70B (70B trained 1 epoch)LLaMA-3 + LoRA · FindingsGREEN: 68.8 -> 63.3Hurt
add LoRA over Prefix+ICL for LLaMA-3-70BLLaMA-3-70B · ImpressionGREEN: 89.2 -> 75.8Hurt
biomedical + radiology pretraining instead of general-text init (ablation)BERT2BERT · structured reportsGREEN: +4.5%Improved
radiology-only pretraining (RadBERT) instead of general-text init (ablation)BERT2BERT · structured reportsGREEN: +0.3%No clear effect
biomedical-text initialization (SciFive) instead of T5-Base (ablation)T5 · structured reportsGREEN: -2.4%Hurt
radiology-only pretraining (Clin-T5-Base) instead of T5-Base (ablation)T5 · structured reportsGREEN: +4.4%Improved
combine LoRA finetuning with prompting methods (ablation)LLMs · structured reportsperformanceNo clear effect

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy