Research map / Large language models / AI and society
Beyond Scalar Scores: Exploring LLM-based Metrics for Clinical Significance Evaluation in Radiology Reports
Qingyu Lu, Ruochen Li, Liang Ding, Yufei Xia, Youxiang Zhu, Dacheng Tao
Nanyang Technological University · Technical University of Munich · University of Glasgow
Read the paperPlace an idea next to itCheck your own paper ↗
13measured effects
7improved
5hurt
1mixed
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| replace score-based metrics with an LLM evaluator (Claude Sonnet 4.5, 1-pass) | report evaluation metric · ReEvalMed | Discrimination / Robustness accuracy: CRIMSON best score-based 75.0/80.5 vs Claude 91.5/84.0 | Improved |
| use LLM evaluators zero-shot (1-pass) | most LLM evaluators · ReEvalMed | Robustness accuracy: R from 8.0 to 84.0 across models, most below 60 | Hurt |
| switch from 1-pass to 2-pass inference (ablation) | GPT-5.1 · ReEvalMed | D-R gap: 56.0 -> 25.5 | Improved |
| switch from 1-pass to 2-pass inference (ablation) | Claude Sonnet 4.5 · ReEvalMed | D-R gap: 7.5 -> 47.0 | Hurt |
| switch from 1-pass to 2-pass inference (ablation) | LingShu-32B · ReEvalMed | D-R gap: 35.5 -> 92.0 | Hurt |
| add SFT on synthesized 4k pairs (ablation) | Qwen3-8B, 2-pass · ReEvalMed | Avg of D and R (%): 52.3 -> 68.0 | Improved |
| add DPO (RL) after SFT (ablation) | Qwen3-8B, 2-pass · ReEvalMed | Avg of D and R (%): 68.0 -> 74.5 (Gap 32.0 -> 8.0) | Improved |
| add SFT on synthesized pairs (ablation) | MedGemma-4B, 1-pass · ReEvalMed | Robustness accuracy (%): R 9.0 -> 93.0, D 49.0 -> 60.5 | Mixed |
| add DPO (RL) after SFT (ablation) | MedGemma-4B, 1-pass · ReEvalMed | Avg of D and R (%): 76.8 -> 77.8 (Gap 32.5 -> 4.5) | Improved |
| add DPO (RL) after SFT (ablation) | MedGemma-4B, 2-pass · ReEvalMed | D-R gap: 17.0 -> 24.0 | Hurt |
| use 2-pass instead of 1-pass for trained Qwen3-8B (ablation) | Qwen3-8B + SFT + RL · ReEvalMed | D-R gap: 46.5 -> 8.0 | Improved |
| use 2-pass instead of 1-pass for trained MedGemma-4B (ablation) | MedGemma-4B + SFT + RL · ReEvalMed | D-R gap: 4.5 -> 24.0 | Hurt |
Closest papers by meaning
- GEMA-Score: Granular Explainable Multi-Agent Scoring Framework for Radiology Report Evaluation (AAAI 2026 · similarity 0.88)
- Image-aware Evaluation of Generated Medical Reports (NeurIPS 2024 · similarity 0.87)
- HC-LLM: Historical-Constrained Large Language Models for Radiology Report Generation (AAAI 2025 · similarity 0.87)
- LLM-RG4: Flexible and Factual Radiology Report Generation Across Diverse Input Contexts (AAAI 2025 · similarity 0.87)
- Reporting Practice Matters: The Impact of Reference Choice on Chest X-ray Report Evaluation (NeurIPS 2026 · similarity 0.86)
- ReFINE: A Reward-Based Framework for Interpretable and Nuanced Evaluation of Radiology Report Generation (AAAI 2026 · similarity 0.86)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
