AI Paper Atlas

Research map / Multi-agent systems and games / LLM agents

Beyond Fresh Starts: Stateful Inference for Streaming ASR in Conversational Voice Agents

EMNLP 2026Multi-agent systems and games › LLM agentsapproach: Agentic benchmarks and orchestration1 citations (OpenAlex)

Read the paperPlace an idea next to itCheck your own paper ↗

12measured effects
6improved
2no clear effect
3hurt
1mixed

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Carry state across turns (SC) instead of resetting (FS)fastconformer-114m · Switchboard testFirst Word WER: 51.44 -> 35.92Improved
Carry state across turns (SC) instead of resetting (FS)nemotron-streaming-0.6b · CallHome testOverall WER: 13.82 -> 13.86No clear effect
Roll back to last substantial-turn state (RB) instead of FSnemotron-streaming-0.6b · CallHome testFirst Word WER: 32.28 -> 27.85Improved
Add rollback (RB) on top of carry-over (SC) (ablation)nemotron-streaming-0.6b · CallHome testFirst Word WER: 32.36 -> 27.85Improved
Add rollback (RB) on top of carry-over (SC) (ablation)fastconformer-114m · Switchboard testOverall WER: 10.26 -> 10.20No clear effect
Continuous state (CS) instead of resetting (FS)fastconformer-114m · Switchboard testAfter Long Pause WER: 14.73 -> 20.06Hurt
Continuous state (CS) instead of resetting (FS)fastconformer-114m · Switchboard testOverall WER: 11.97 -> 12.36Hurt
Continuous state (CS) instead of resetting (FS)fastconformer-114m · Switchboard testFirst Word WER: 51.44 -> 44.32Improved
Increase rollback threshold k from 1 to 10 (ablation)nemotron-streaming-0.6b · Switchboard testOverall WER: 10.80 -> 10.62Improved
Lower latency from 560 ms to 160 ms with RB (ablation)State Rollback · Switchboard/CallHomeOverall WER: WER increase below 6% for both modelsMixed
Use RB at 560 ms latency instead of FS (ablation)nemotron-streaming-0.6b · Switchboard testOverall WER: 10.08 (FS) vs 10.67 (RB)Hurt
Use Silero-VAD turn boundaries instead of ground-truth timings with RBState Rollback · Switchboard testFirst Word WER vs FS: 20.6% relative reduction (VAD) vs 20.9% (ground-truth)Improved

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy