AI Paper Atlas

Research map / 3D vision / Depth and stereo

Multi-view Surface Reconstruction Using Normal and Reflectance Cues

Robin Bruneau, Baptiste Brument, Yvain Quéau, Jean Mélou, François Lauze, Jean‐Denis Durou, Lilian Calvet

IJCV 2026 · 3D vision › Depth and stereo · approach: Photometric stereo · 5 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
use L2 NVR loss instead of L1 (normals only, optimal triplets) (ablation)RNb-NeuS2 · DiLiGenT-MVChamfer distance (mm): 0.252 -> 0.194Improved
use L2 NVR loss instead of L1 (normals only, optimal triplets) (ablation)RNb-NeuS2 · LUCES-MVChamfer distance (mm): 0.540 -> 0.431Improved
use optimal lighting triplets instead of canonical (L1, normals only) (ablation)RNb-NeuS2 · DiLiGenT-MVChamfer distance (mm): 0.267 -> 0.252Improved
use optimal lighting triplets instead of canonical (L2, normals only) (ablation)RNb-NeuS2 · DiLiGenT-MVChamfer distance (mm): 0.196 -> 0.194No clear effect
add reflectance maps to normals under L1 loss (ablation)RNb-NeuS2 · DiLiGenT-MVChamfer distance (mm): 0.252 -> 0.241Improved
add reflectance maps to normals under L2 loss (ablation)RNb-NeuS2 · DiLiGenT-MVChamfer distance (mm): 0.194 -> 0.221Hurt
add reflectance maps to normals under L2 loss (ablation)RNb-NeuS2 · LUCES-MVChamfer distance (mm): 0.431 -> 0.409Mixed
add reflectance embedding (+) to reflectance parametrisation (ablation)RNb-NeuS2 · DiLiGenT-MVChamfer distance (mm): 0.221 -> 0.209Improved
replace SDM-UniPS normals with UniMS-PS normalsRNb-NeuS2 · DiLiGenT-MVChamfer distance (mm): 0.194 -> 0.167Improved
replace SDM-UniPS normals with UniMS-PS normalsRNb-NeuS2 · LUCES-MVChamfer distance (mm): 0.431 -> 0.362Improved
reduce views from 20 to 5 for the proposed method (UniMS-PS)RNb-NeuS2 · DiLiGenT-MVChamfer distance (mm): 0.167 -> 0.217Hurt
use ground-truth normals instead of estimated normals (SDM)RNb-NeuS2 · DiLiGenT-MVChamfer distance (mm): 0.194 -> 0.093Improved

Earlier methods this paper compares with

Named baselines from earlier accepted papers in this paper's results tables: better than 1 of 2 on most shared results.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy