Research map / Probabilistic and scientific modeling / Uncertainty and Gaussian processes
Inferring Bias and Uncertainty in Camera Calibration
Annika Hagemann, Moritz Knorr, Holger Janssen, Christoph Stiller
Read the paperCheck your idea against 137,217 papers
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| use camera model C(5) instead of C(3) on rendered images (ablation) | calibration with bias ratio · Rendered images | bias ratio: BR close to one -> BR approx 0.6 | Improved |
| use C(6) with two radial distortion parameters instead of C(5) (ablation) | calibration with bias ratio · Rendered images | bias ratio: BR approx 0.6 -> BR < 0.2 | Improved |
| add parameters C(7), C(8) beyond C(6) (ablation) | camera model · Rendered images | bias ratio | No clear effect |
| use precisely measured board geometry instead of assuming planar board (ablation) | calibration · Real lenses | bias ratio | Improved |
| use bias ratio rather than RMSE alone to judge calibration | bias detection · Real lenses | detection of systematic error: RMSE below 0.1 pixels yet BR remained high | Improved |
| use bootstrap (BS) or approximated bootstrap (aBS) instead of the standard covariance estimator | uncertainty estimation · Simulated underfit and real cameras | EME vs true error | Improved |
| use BS/aBS instead of standard estimator | uncertainty estimation · Ideal simulation (no systematic errors) | EME vs true error | No clear effect |
| use aBS covariance in EME with few images (N_F <= 15) | EME · Real lenses | EME vs true error: overestimates true error for N_F <= 15 | Hurt |
| replace trace(Sigma) with EME for calibration guidance after reparametrizing focal length by 0.01*f | calibration wizard · Simulated guidance | uncertainty reduction speed | Improved |
| EME-guided or trace-guided image selection instead of random images | calibration wizard · Pinhole with radial distortion | uncertainty reduction | Improved |
Closest papers by meaning
- Systematic Evaluation of Uncertainty Calibration in Pretrained Object Detectors (IJCV 2024 · similarity 0.86)
- Calibration Wizard: A Guidance System for Camera Calibration Based on Modelling Geometric and Corner Uncertainty (ICCV 2019 · similarity 0.86)
- Improving model calibration with accuracy versus uncertainty optimization (NeurIPS 2020 · similarity 0.86)
- A Perceptual Measure for Deep Single Image Camera Calibration (CVPR 2018 · similarity 0.86)
- A Perceptual Measure for Deep Single Image Camera and Lens Calibration (TPAMI 2023 · similarity 0.85)
- Unbiased Estimator for Distorted Conics in Camera Calibration (CVPR 2024 · similarity 0.85)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.