Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add shallow stem before tube tokenization (ablation) | PhysFormer · VIPL-HR (Fold-1) | RMSE (bpm): 10.62 -> 7.56 | Improved |
| add TD-MHSA instead of vanilla MHSA (ablation) | PhysFormer · VIPL-HR (Fold-1) | RMSE (bpm): 10.43 -> 7.56 | Improved |
| add spatio-temporal attention (ablation) | PhysFormer · VIPL-HR (Fold-1) | RMSE (bpm): 9.81 -> 7.56 | Improved |
| add ST-FF instead of vanilla FF (ablation) | PhysFormer · VIPL-HR (Fold-1) | RMSE (bpm): 8.27 -> 7.56 | Improved |
| replace TD-MHSA with TD-MHPSA without attention loss (ablation) | PhysFormer++ slow pathway · VIPL-HR (Fold-1) | RMSE (bpm): 7.56 -> 7.69 | Hurt |
| add periodic attention loss L_atten to TD-MHPSA (ablation) | PhysFormer++ slow pathway · VIPL-HR (Fold-1) | RMSE (bpm): 7.69 -> 7.43 | Improved |
| add L_atten to TD-MHPSA in fast pathway (ablation) | PhysFormer++ fast pathway · VIPL-HR (Fold-1) | RMSE (bpm): 8.12 -> 7.85 | Mixed |
| use naive two-pathway SlowFast without interaction (ablation) | PhysFormer++ · VIPL-HR (Fold-1) | RMSE (bpm): 7.56 -> 7.78 | Hurt |
| add lateral connection at high level (ablation) | PhysFormer++ · VIPL-HR (Fold-1) | RMSE (bpm): 7.58 -> 7.34 | Improved |
| add TD-MHCSA at Mid&High-level (ablation) | PhysFormer++ · VIPL-HR (Fold-1) | RMSE (bpm): 7.34 -> 7.16 | Improved |
| use exponentially increasing frequency-loss weight instead of fixed (ablation) | PhysFormer · VIPL-HR (Fold-1) | RMSE (bpm): 8.48 -> 7.56 | Improved |
| add label distribution loss L_LD to CE (ablation) | PhysFormer · VIPL-HR (Fold-1) | RMSE (bpm): 8.09 -> 7.56 | Improved |
Closest papers by meaning
- PhysFormer: Facial Video-Based Physiological Measurement With Temporal Difference Transformer (CVPR 2022 · similarity 0.99)
- RhythmMamba: Fast, Lightweight, and Accurate Remote Physiological Measurement (AAAI 2025 · similarity 0.92)
- Remote Photoplethysmography in Real-World and Extreme Lighting Scenarios (CVPR 2025 · similarity 0.92)
- PhysDiff: Physiology-based Dynamicity Disentangled Diffusion Model for Remote Physiological Measurement (AAAI 2025 · similarity 0.91)
- FacePhys: State of the Heart Learning (NeurIPS 2026 · similarity 0.90)
- FactorizePhys: Matrix Factorization for Multidimensional Attention in Remote Physiological Sensing (NeurIPS 2024 · similarity 0.89)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.