Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add time-binning (transient information) to DOT measurements (ablation) | DOT Jacobian · Simulated Jacobian conditioning | minimum singular value: 67 to 82 | Improved |
| restrict to confocal (collocated) source-detector pairs (ablation) | ToF-DOT · Simulated Jacobian conditioning | minimum singular value: 82 to 1276 | Improved |
| use confocal geometry with convolutional approximation instead of full source-detector pairs | ToF-DOT · Experimental 2D absorber reconstruction | inverse solver runtime: ~1 sec to ~8 ms | Improved |
| use 32x32 confocal scan instead of 10x10 all-pairs scan | ToF-DOT · Experimental 2D absorber reconstruction | scan points / image quality: 10,000 to 1024 scan points with comparable quality | Improved |
| add source multiplexing | CToF-DOT · Multiplexing experiment (5 mm phantom) | integration time for comparable PSNR: 100 ms to 10 ms, overall ~5 times reduction in capture time | Improved |
| add time-binning (time-gating) to fluorescence imaging (ablation) | CToF-DOT · Oval-line fluorescence scene | reconstruction quality | Improved |
| add time-domain data (CToF-DOT vs DOT with 4 mm separation, no temporal data) (ablation) | DOT · Simulated fluorescent line resolution test | spatial resolution: two 0.5 mm lines resolved | Improved |
| replace Jacobian forward model with convolutional forward model | 3D CToF-DOT reconstruction · Simulated 3D reconstruction | runtime: almost an order of magnitude faster, comparable image quality | Improved |
| add layer-wise (depth-dependent) regularization lambda(z) (ablation) | 3D FISTA reconstruction · Simulated 3D reconstruction | deep-layer recovery | Improved |
| multiplex up to 4 distant sources with no cross-talk | CToF-DOT · Prototype with 5 cm FOV | capture time: 4x improvement in total capture time | Improved |
Closest papers by meaning
- Single Exposure Quantitative Phase Imaging with a Conventional Microscope Using Diffusion Models (AAAI 2025 · similarity 0.83)
- Learnable Burst-Encodable Time-of-Flight Imaging for High-Fidelity Long-Distance Depth Sensing (NeurIPS 2025 · similarity 0.81)
- CD-RCM: Generalizable Continuous-Depth Novel View Synthesis for Reflectance Confocal Microscopy (NeurIPS 2026 · similarity 0.81)
- OpticalNet: An Optical Imaging Dataset and Benchmark Beyond the Diffraction Limit (CVPR 2025 · similarity 0.81)
- MicroDiffusion: Implicit Representation-Guided Diffusion for 3D Reconstruction from Limited 2D Microscopy Projections (CVPR 2024 · similarity 0.81)
- Separating the Wheat from the Chaff: Spatio-Temporal Transformer with View-interweaved Attention for Photon-Efficient Depth Sensing (AAAI 2025 · similarity 0.81)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.