Research map / Video / Video segmentation and tracking
Contrast-Phys+: Unsupervised and Weakly-Supervised Video-Based Remote Physiological Measurement via Spatiotemporal Contrast
Zhaodong Sun, Xiaobai Li
Read the paperCheck your idea against 137,217 papers
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add HR range constraint (ablation) | Contrast-Phys+ (0%) · UBFC-rPPG | MAE (bpm): 39.66 -> 0.64 | Improved |
| add rPPG cross-video dissimilarity (negative loss) (ablation) | Contrast-Phys+ (0%) · UBFC-rPPG | MAE (bpm): 22.11 -> 0.64 | Improved |
| add rPPG temporal similarity (ablation) | Contrast-Phys+ (0%) · UBFC-rPPG | MAE (bpm): 1.26 -> 0.64 | Improved |
| add rPPG spatial similarity (2x2 instead of 1x1 resolution) (ablation) | Contrast-Phys+ (0%) · UBFC-rPPG | MAE (bpm): 3.14 -> 0.64 | Improved |
| use 10s ST-rPPG time length instead of 30s (ablation) | Contrast-Phys+ (0%) · UBFC-rPPG | MAE (bpm): 1.97 -> 0.64 | Improved |
| use rPPG sample length T/2 instead of T/4 (ablation) | Contrast-Phys+ (0%) · UBFC-rPPG | MAE (bpm): 0.98 -> 0.64 | Improved |
| add GT-rPPG positive loss (ablation) | Contrast-Phys+ (100%) · MMSE-HR | MAE (bpm): 1.82 -> 1.39 | Improved |
| add GT-rPPG negative loss (ablation) | Contrast-Phys+ (100%) · MMSE-HR | MAE (bpm): 1.82 -> 1.77 | Improved |
| add both GT-related positive and negative losses (ablation) | Contrast-Phys+ (100%) · MMSE-HR | MAE (bpm): 1.82 -> 1.11 | Improved |
| add unlabeled PURE videos to labeled UBFC training | Contrast-Phys+ (100%) · MMSE-HR (cross-dataset) | MAE (bpm): 1.76 -> 1.13 | Improved |
| add unlabeled OBF videos to labeled UBFC training | Contrast-Phys+ (100%) · MMSE-HR (cross-dataset) | MAE (bpm): 1.76 -> 1.47 | Improved |
| add unlabeled MMSE-HR to labeled SCAMPS training | Contrast-Phys+ · UBFC-rPPG | MAE (bpm): 0.89 -> 0.51 | Improved |
Earlier methods this paper compares with
Named baselines from earlier accepted papers in this paper's results tables: better than 1 of 1 on most shared results.
- PhysFormer — PhysFormer: Facial Video-Based Physiological Measurement With Temporal Difference Transformer (CVPR 2022) · better on 1 of 1 shared result
Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.
Closest papers by meaning
- Contrast-Phys: Unsupervised Video-Based Remote Physiological Measurement via Spatiotemporal Contrast (ECCV 2022 · similarity 0.98)
- The Way to My Heart Is Through Contrastive Learning: Remote Photoplethysmography From Unlabelled Video (ICCV 2021 · similarity 0.95)
- PhysFormer: Facial Video-Based Physiological Measurement With Temporal Difference Transformer (CVPR 2022 · similarity 0.93)
- PhysDiff: Physiology-based Dynamicity Disentangled Diffusion Model for Remote Physiological Measurement (AAAI 2025 · similarity 0.91)
- Remote Photoplethysmography in Real-World and Extreme Lighting Scenarios (CVPR 2025 · similarity 0.90)
- RhythmMamba: Fast, Lightweight, and Accurate Remote Physiological Measurement (AAAI 2025 · similarity 0.90)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
