Research map / Vision-language and multimodal / Multimodal LLMs
Seeing What Matters: Lesion-Aware High-Resolution Patch Discovery and Fusion for Chest X-ray Report Generation
Yingshu Li, YUNYI LIU, Zhenghao Chen, Tong Chen, Zailong Chen, Lingqiao Liu, Lei Wang, Luping Zhou
Read the paperCheck your idea against 137,217 papers
AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.
Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add Global-Regional Fusion with randomly sampled high-res patches (ablation) | BLIP-3 RRG baseline · MIMIC-CXR | BLEU-4: 0.237 -> 0.243 | Improved |
| select patches with learned LSRA utility map instead of Grad-CAM (both with GRF) (ablation) | LePaX · MIMIC-CXR | BLEU-4: 0.251 -> 0.253 | Improved |
| add policy supervision (Grad-CAM prior) to LSRA training (ablation) | LePaX · MIMIC-CXR | BLEU-4: 0.246 -> 0.253 | Improved |
| concatenate patch tokens instead of GRF write-back (ablation) | LePaX · MIMIC-CXR | BLEU-4: 0.253 -> 0.235 (LSRA, no GRF) | Hurt |
| increase uniform input resolution from 384 to 1024 (ablation) | BLIP-3 RRG baseline · MIMIC-CXR | BLEU-4: 0.237 -> 0.240 | No clear effect |
| use LePaX allocation at native resolution 1920 versus 1024 (ablation) | LePaX · MIMIC-CXR | BLEU-4: 0.245 -> 0.253 | Improved |
| increase number of high-res patches Top-K beyond 5 (ablation) | LePaX · MIMIC-CXR | BLEU-4 | Hurt |
| LePaX versus MambaXray-VL-L on CheXpertPlus ROUGE | LePaX · CheXpertPlus (CXPMRG-Bench) | ROUGE: 0.276 -> 0.252 | Hurt |
| LePaX versus prior methods on MIMIC-CXR NLG | LePaX · MIMIC-CXR | BLEU-4: 0.193 -> 0.253 | Improved |
Earlier methods this paper compares with
Named baselines from earlier accepted papers in this paper's results tables: better than 1 of 1 on most shared results.
- DAMPER — DAMPER: A Dual-Stage Medical Report Generation Framework with Coarse-Grained MeSH Alignment and Fine-Grained Hypergraph Matching (AAAI 2025) · better on 3 of 3 shared results
Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.
Closest papers by meaning
- A Disease-Aware Dual-Stage Framework for Chest X-ray Report Generation (AAAI 2026 · similarity 0.87)
- Rethinking Visual Attribution for Chest X-ray Reasoning in Large Vision Language Models (NeurIPS 2026 · similarity 0.85)
- CXReasonBench: A Benchmark for Evaluating Structured Diagnostic Reasoning in Chest X-rays (NeurIPS 2025 · similarity 0.85)
- Enhanced Contrastive Learning with Multi-view Longitudinal Data for Chest X-ray Report Generation (CVPR 2025 · similarity 0.85)
- BenchX: A Unified Benchmark Framework for Medical Vision-Language Pretraining on Chest X-Rays (NeurIPS 2024 · similarity 0.85)
- Addressing Asynchronicity in Clinical Multimodal Fusion via Individualized Chest X-ray Generation (NeurIPS 2024 · similarity 0.84)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.
