What was changedWhereMeasuredEffect
train a unisex model instead of a female-only model (ablation)joint optimization shape model · FAUST intra-subject challengeaverage error (cm): 2.353 -> 2.304Improved
train a unisex model instead of a female-only model (ablation)joint optimization shape model · FAUST inter-subject challengeaverage error (cm): 3.234 -> 3.525Hurt
train a male-only model instead of female-only (ablation)joint optimization shape model · FAUST inter-subject challengeaverage error (cm): 3.234 -> 3.519Hurt
combine female and male models instead of female only (ablation)joint optimization shape model · FAUST intra-subject challengeaverage error (cm): 2.353 -> 2.301Improved
combine female and male models instead of female only (ablation)joint optimization shape model · FAUST inter-subject challengeaverage error (cm): 3.234 -> 3.422Hurt
use ours (female) instead of LBS-AEFAUST inter-subject · FAUST inter-subject challengeaverage error (cm): 4.079 -> 3.234Improved
use ours (female) instead of unsupervised 3D-CODEDFAUST inter-subject · FAUST inter-subject challengeaverage error (cm): 4.835 -> 3.234Improved
use ours (female) instead of supervised 3D-CODEDFAUST inter-subject · FAUST inter-subject challengeaverage error (cm): 2.878 -> 3.234Hurt
use Deprelle et al. instead of ours (female)FAUST intra-subject · FAUST intra-subject challengeaverage error (cm): 2.353 -> 1.626Hurt
add shape blend-shape principal components from 0 to 10 (ablation)trained female model · training scansreconstruction error (mm): 3.7 mm with all 10 componentsImproved