Measured effects reported in the paper

What was changedWhereMeasuredEffect
add rPPG-signal supervision (multi-task) to HR-only training (ablation)MSTmap network · VIPL-HR (5-fold, average HR)MAE (bpm): 6.39 -> 5.55Improved
add rPPG-signal supervision (multi-task) to HR-only training (ablation)MSTmap network · VIPL-HR (5-fold, average HR)RMSE (bpm): 10.24 -> 9.03Improved
add cross-verified disentangling (CVD) (ablation)MSTmap+MTL · VIPL-HR (5-fold, average HR)RMSE (bpm): 9.03 -> 7.97Improved
add cross-verified disentangling (CVD) (ablation)MSTmap+MTL · VIPL-HR (5-fold, average HR)MAE (bpm): 5.55 -> 5.02Improved
add cross-verified disentangling (CVD) (ablation)STmap+MTL · VIPL-HR (5-fold, average HR)RMSE (bpm): 9.01 -> 8.51Improved
use MSTmap instead of STmap input (ablation)MTL without CVD · VIPL-HR (5-fold, average HR)MAE (bpm): 5.80 -> 5.55Improved
use MSTmap instead of STmap input (ablation)MTL with CVD · VIPL-HR (5-fold, average HR)RMSE (bpm): 8.51 -> 7.97Improved
add pre-defined head movement signal disentanglement (ablation)MSTmap+MTL · VIPL-HR (5-fold, average HR)RMSE (bpm): 9.03 -> 8.96Improved
add pre-defined face pixel std signal disentanglement (ablation)MSTmap+MTL · VIPL-HR (5-fold, average HR)RMSE (bpm): 9.03 -> 8.72Improved
use CVD instead of pre-defined non-physiological signals (ablation)MSTmap+MTL · VIPL-HR (5-fold, average HR)RMSE (bpm): 8.72 -> 7.97Improved
use proposed method instead of RhythmNetRhythmNet · VIPL-HR (5-fold, average HR)RMSE (bpm): 8.14 -> 7.97Improved
use proposed method instead of RhythmNet in large head movement scenarioRhythmNet · VIPL-HR (large head movement)RMSE (bpm): 9.4 -> 7.44Improved