AI Paper Atlas

Research map / Architectures and efficiency / Attention and transformers

A Rotation-invariant Texture ViT for Fine-Grained Recognition of Esophageal Cancer Endoscopic Ultrasound Images

Tianyi Liu, Shuaishuai S Zhuang, Jiacheng Nie, Geng Chen, Yusheng Guo, Guangquan Zhou, Jean-Louis Coatrieux, Yang Chen

ECCV 2024 · Architectures and efficiency › Attention and transformers · approach: Token merging and masked pretraining · 0 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add token selection module to ViT (ablation)ViT-B 16 · In-house EUS datasetaccuracy (%): 61.6 -> 76.3Improved
add rotation-invariant reinforcement (soft histogram) to ViT+TS (ablation)ViT+TS · In-house EUS datasetaccuracy (%): 76.3 -> 77.4Improved
add contrastive loss to ViT+TS+RR (ablation)SRRM-ViT · In-house EUS datasetaccuracy (%): 77.4 -> 78.7Improved
add rotation-invariant reinforcement to ViT+TS+Lcon (ablation)ViT+TS+Lcon · In-house EUS datasetaccuracy (%): 77.9 -> 78.7Improved
add reinforcement to ViT+TS+Lcon (ablation)SRRM-ViT · In-house EUS datasetrecall (%): 41.8 -> 41.1No clear effect
add rotation-invariant reinforcement (ablation)ViT+TS · In-house EUS datasetFLOPs (G): 17.0 -> 32.5Hurt
use 8 histogram bins instead of 4 (ablation)SRRM-ViT · In-house EUS datasetaccuracy (%): 75.6 -> 78.7Improved
use 16 histogram bins instead of 8 (ablation)SRRM-ViT · In-house EUS datasetaccuracy (%): 78.7 -> 76.2Hurt
set contrastive margin alpha to 0.7 instead of 0.3 (ablation)SRRM-ViT · In-house EUS datasetaccuracy (%): 75.6 -> 78.7Improved
raise alpha from 0.7 to 0.9 (ablation)SRRM-ViT · In-house EUS datasetaccuracy (%): 78.7 -> 76.5Hurt
apply SRRM-ViT instead of plain ViT on Brain Tumor MRIViT-B 16 · Brain Tumor MRIaccuracy (%): 96.9 -> 99.2Improved
SRRM-ViT versus CSA-MLP on Brain Tumor MRI recallSRRM-ViT · Brain Tumor MRIrecall (%): 87.8 vs 98.5Hurt

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy