AI Paper Atlas

Research map / 3D vision / Human pose estimation

Full-Body Articulated Human-Object Interaction

Nan Jiang, Tengyu Liu, Zhexuan Cao, Jieming Cui, Zhiyuan Zhang, Yixin Chen, He Wang, Yixin Zhu, Siyuan Huang

ICCV 2023 · 3D vision › Human pose estimation · approach: Physics and sensor-based motion capture · 75 citations (OpenAlex)

Read the paperCheck your idea against 137,217 papers

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
add interaction prior (cVAE) to pose optimization (ablation)Ours (w/ opt.) · CHAIRS test (w/ opt, known object structure)chamfer distance: 87.90 -> 72.30Improved
add interaction prior to pose optimization (ablation)Ours (w/ opt.) · CHAIRS test (w/ opt, known object structure)IoU: 18.81 -> 21.57Improved
add interaction prior to pose optimization (ablation)Ours (no object knowledge) · CHAIRS test (w/o opt, no object knowledge)chamfer distance: 165.3 -> 160.2Improved
add interaction prior to pose optimization (ablation)Ours (no object knowledge) · CHAIRS test (w/o opt, no object knowledge)contact: 3.295 -> 2.720Improved
add interaction prior to pose optimization (ablation)Ours (no object knowledge) · CHAIRS test (w/o opt, no object knowledge)penetration: 4.377 -> 4.530Hurt
add contrastive loss to prior training (ablation)Ours (w/ opt.) · CHAIRS test (w/ opt, known object structure)chamfer distance: 87.28 -> 72.30Improved
add contrastive loss to prior training (ablation)Ours (w/ opt.) · CHAIRS test (w/ opt, known object structure)contact: 2.393 -> 1.562Improved
add interaction awareness (concatenate human voxels) (ablation)Ours (w/ opt.) · CHAIRS test (w/ opt, known object structure)chamfer distance: 78.12 -> 72.30Improved
add interaction awareness (concatenate human voxels) (ablation)Ours (w/ opt.) · CHAIRS test (w/ opt, known object structure)rotation error: 17.88 -> 19.35Hurt
add interaction awareness (concatenate human voxels) (ablation)Ours (w/ opt.) · CHAIRS test (w/ opt, known object structure)penetration: 1.022 -> 1.143Hurt
replace PARE human pose with ground-truth human pose (ablation)Ours (w/ opt.) · CHAIRS test (w/ opt, known object structure)chamfer distance: 72.30 -> 65.50Improved
use PARE human pose instead of none (no prior baseline) (ablation)Ours · CHAIRS test (w/ opt, known object structure)chamfer distance: 87.90 -> 73.79Improved

Earlier methods this paper compares with

Named baselines from earlier accepted papers in this paper's results tables: better than 1 of 1 on most shared results.

Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy