AI Paper Atlas

Research map / 3D vision / Human pose estimation

Single View Physical Distance Estimation Using Human Pose

Xiaohan Fei, Henry Wang, Lin Lee Cheong, Xiangyu Zeng, Meng Wang, Joseph Tighe

ICCV 2021 · 3D vision › Human pose estimation · approach: Multi-person pose estimation · 10 citations (OpenAlex)

Read the paper

AI-extracted. The measured effects below were read by AI from the paper's full text (no summary yet). Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Measured effects reported in the paper

What was changedWhereMeasuredEffect
use direct linear solver instead of line intersection and fittingpose-based calibration · Simulation noise std 0.5 pxfocal length error f_x (%): 4.58 -> 3.11Improved
use direct linear solver instead of line intersection and fittingpose-based calibration · Simulation noise std 5.0 pxfocal length error f_x (%): 32.69 -> 28.03Improved
use direct linear solver instead of line intersection and fittingpose-based calibration · Simulation noise std 5.0 pxfailure rate (%): 27.28 -> 13.72Improved
aggregate more people measurementsdirect linear solver · Simulation, number of peoplefailure rate (%): 9.88 -> 1.52Improved
aggregate more people measurementsdirect linear solver · Simulation, number of people3-D point error X (%): 16.31 -> 9.31Improved
add lens distortion modeling (ablation)direct linear solver · Simulation k1=1e-3focal length error f_x (%): 0.16 -> 1.077e-5Improved
add lens distortion modeling (ablation)direct linear solver · Simulation k1=-1e-3focal length error f_y (%): 0.020 -> 0.0019Improved
add lens distortion modeling (ablation)direct linear solver · Simulation noisy measurementsfailure rateHurt
use pose-based geometric estimator instead of fine-tuned ResNet classifierdistance estimation · MEVADA test setaccuracy: 0.40 -> 0.78Improved
use direct solver instead of prior line-based methodcalibration · vPTZ set1-cam-132focal length error (%): 10.14% -> 0.35 %Improved
use direct solver instead of prior line-based methodcalibration · POM terrace1-cam0focal length error (%): 1.43% -> 2.51%Hurt