Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| add local representations to global at inference (ablation) | GLoRIA · CheXpert 5x200 retrieval | Prec@5: 67.02 -> 69.24 | Improved |
| add local representations to global at inference (ablation) | GLoRIA · CheXpert 5x200 retrieval | Prec@100: 49.55 -> 53.78 | Improved |
| add global representations to local only (ablation) | GLoRIA · CheXpert 5x200 retrieval | Prec@10: 64.58 -> 67.22 | Improved |
| add local contrastive loss to global-only contrastive training (vs ConVIRT) with global features | GLoRIA · CheXpert 5x200 retrieval | Prec@5: 66.98 -> 67.02 | No clear effect |
| use GLoRIA instead of ConVIRT | GLoRIA · RSNA fine-tuned classification (1% labels) | AUROC (%): 77.4 -> 86.1 | Improved |
| use GLoRIA instead of ConVIRT | GLoRIA · CheXpert fine-tuned classification (1% labels) | AUROC (%): 85.9 -> 86.6 | Improved |
| use GLoRIA 1% labels instead of ImageNet init with 100% labels | GLoRIA · CheXpert fine-tuned classification | AUROC (%): 81.4 -> 86.6 | Improved |
| use GLoRIA initialization instead of ConVIRT | GLoRIA · SIIM pneumothorax segmentation (1% labels) | Dice: 0.250 -> 0.358 | Improved |
| use GLoRIA initialization instead of ConVIRT | GLoRIA · SIIM pneumothorax segmentation (10% labels) | Dice: 0.432 -> 0.469 | Improved |
| use GLoRIA instead of ImageNet initialization with full labels | GLoRIA · SIIM pneumothorax segmentation (100% labels) | Dice: 0.635 -> 0.634 | No clear effect |
| use zero-shot GLoRIA instead of fine-tuned classifier with 100% labels | GLoRIA · CheXpert 5x200 classification | F1: 0.63 -> 0.67 | Improved |
| use zero-shot GLoRIA instead of fine-tuning on 1% labels | GLoRIA · RSNA classification | F1: 0.57 -> 0.58 | No clear effect |
Later papers that compared with this method
2 later accepted papers report GLoRIA as a baseline in their results tables; 1 of them report a better number on most of the results they share with it.
- Integrating Prior Knowledge in Contrastive Learning with Kernel (ICML 2023 · better on 1 of 2 shared results)
- Advancing Radiograph Representation Learning with Masked Record Modeling (ICLR 2023 · better on 1 of 1 shared result)
Matched by method name in results tables read by AI. Authors' own tables tend to favour the newer method, and a comparison can be missed when a method is renamed.
Closest papers by meaning
- Unlocking the Power of Spatial and Temporal Information in Medical Multimodal Pre-training (ICML 2024 · similarity 0.86)
- G2D: From Global to Dense Radiography Representation Learning via Vision-Language Pre-training (NeurIPS 2024 · similarity 0.86)
- Large-scale and Fine-grained Vision-language Pre-training for Enhanced CT Image Understanding (ICLR 2025 · similarity 0.86)
- Autoregressive Sequence Modeling for 3D Medical Image Representation (AAAI 2025 · similarity 0.85)
- MedMO: Grounding and Understanding Multimodal Large Language Model for Medical Images (CVPR 2026 · similarity 0.85)
- Interpretable Bilingual Multimodal Large Language Model for Diverse Biomedical Tasks (ICLR 2025 · similarity 0.85)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.