Measured effects reported in the paper

What was changedWhereMeasuredEffect
add orthogonal tangent regularity (ablation)MAET (YOLOv3) · VOC07 test (synthetic low-light)AP50: 0.770 -> 0.788Improved
add orthogonal tangent regularity (ablation)MAET (YOLOv3) · COCO val (synthetic low-light)AP: 0.321 -> 0.330Improved
add orthogonal tangent regularity (ablation)MAET (YOLOv3) · COCO val (synthetic low-light)AP50: 0.534 -> 0.569Improved
add orthogonal tangent regularity (ablation)MAET (YOLOv3) · COCO val (synthetic low-light)AP_S: 0.163 -> 0.189Improved
add orthogonal tangent regularity (ablation)MAET (YOLOv3) · ExDarkmAP: 0.722 -> 0.740Improved
add orthogonal tangent regularity (ablation)MAET (YOLOv3) · UG2+ DARK FACEmAP: 0.542 -> 0.558Improved
add degradation-decoding task (MAET) without ort, versus detector trained on synthetic low-light only (ablation)YOLOv3 · VOC07 test (synthetic low-light)AP50: 0.764 -> 0.770Improved
add degradation-decoding task (MAET) without ort, versus detector trained on synthetic low-light only (ablation)YOLOv3 · ExDarkmAP: 0.716 -> 0.722No clear effect
add degradation-decoding task (MAET) without ort, versus detector trained on synthetic low-light only (ablation)YOLOv3 · UG2+ DARK FACEmAP: 0.540 -> 0.542No clear effect
use our ISP-based synthesis instead of Retinex synthesis (ablation)YOLO (L) · ExDarkmAP: 0.698 -> 0.716Improved
use our ISP-based synthesis instead of Retinex synthesis (ablation)YOLO (L) · UG2+ DARK FACEmAP: 0.511 -> 0.540Improved
use our synthesis instead of inverse gamma with mixed Gaussian-Poisson noise (ablation)YOLO (L) · UG2+ DARK FACEmAP: 0.535 -> 0.540Improved