What was changedWhereMeasuredEffect
randomly sample 50% of input embeddings for ViT encoder during training instead of 100% (ablation)MimDet-Base · COCO val2017APbox: 51.8 -> 51.5No clear effect
reduce training sampling ratio from 50% to 25% (ablation)MimDet-Base · COCO val2017APbox: 51.5 -> 49.9Hurt
use random sampling instead of grid sampling (ablation)MimDet-Base · COCO val2017APbox: 48.7 -> 51.5Improved
add a short full-input fine-tuning stage after sampled fine-tuning (ablation)MimDet-Base · COCO val2017APbox: 51.5 -> 51.4No clear effect
infer with full input instead of ensembling sampled inferences (ablation)MimDet-Base · COCO val2017APbox: 51.0 (8x50%) -> 51.5 (full)Improved
replace naive ConvStem with ConvNeXt early stage (pretrained or not) (ablation)MimDet-Base · COCO val2017APbox: 51.5 -> 51.3 / 51.4No clear effect
fill unsampled positions with ConvStem features instead of [MASK] tokens (ablation)MimDet-Base · COCO val2017APbox: 51.5 -> 51.7Improved
increase decoder layers from 1 to 4 (ablation)MimDet-Base · COCO val2017APbox: 49.9 -> 51.5Improved
increase decoder layers from 4 to 8 (ablation)MimDet-Base · COCO val2017APbox: 51.5 -> 51.6No clear effect
take FPN high-resolution inputs from ConvStem instead of ViT intermediate features (ablation)MimDet-Base · COCO val2017APbox: 48.9 -> 49.5Improved
use random sampled partial input instead of window partitioned input (ablation)MimDet-Base (1 decoder layer) · COCO val2017APbox: 49.5 -> 49.9Improved
use MimDet instead of prior adapted vanilla ViT detectorMAE ViT-Base · COCO val2017APbox: 50.3 -> 51.7Improved