Measured effects reported in the paper
| What was changed | Where | Measured | Effect |
|---|---|---|---|
| discretize ECG into FSQ tokens (vs continuous embeddings) (ablation) | HeartLLM · Zero-shot ECG-QA QA-Average, MIMIC-IV-ECG to PTB-XL | EM accuracy (%): 35.77 -> 40.71 | Improved |
| use lead-wise ResIncept encoder instead of MultiCNN (ablation) | HeartLLM · ECG-QA QA-Query (MIMIC-IV-ECG) | EM accuracy (%): 16.71 -> 22.05 | Improved |
| use lead-wise ResIncept encoder instead of CausalCNN (ablation) | HeartLLM · ECG-QA QA-Query (PTB-XL) | EM accuracy (%): 29.45 -> 32.55 | Improved |
| use lead-wise encoder instead of independent U-Net 1D (ablation) | HeartLLM · ECG-QA QA-Choose (PTB-XL) | EM accuracy (%): 57.02 -> 59.74 | Improved |
| use lead-wise encoder instead of Unet2D (ablation) | HeartLLM · ECG-QA QA-Choose (PTB-XL) | EM accuracy (%): 59.49 -> 59.74 | No clear effect |
| use HeartLLM versus best baseline | HeartLLM · ECG-QA QA-Query (MIMIC-IV-ECG) | EM accuracy (%): 15.24 -> 22.05 | Improved |
| use HeartLLM versus strongest baseline | HeartLLM · ECG-Report BLEU-4 (MIMIC-IV-ECG) | BLEU-4 (%): 20.60 -> 29.74 | Improved |
| use HeartLLM versus ST-MEM on zero-shot QA-Choose | HeartLLM · Zero-shot PTB-XL QA-Choose | EM accuracy (%): 41.08 (ST-MEM) vs 39.56 | Hurt |
| remove LoRA fine-tuning, remove tabular features (ablations) (ablation) | HeartLLM · PTB-XL ECG-QA/Report | EM accuracy / BLEU | Hurt |
Closest papers by meaning
- ECG-Reasoning-Benchmark: A Benchmark for Evaluating Clinical Reasoning Capabilities in ECG Interpretation (NeurIPS 2026 · similarity 0.90)
- Reading Your Heart: Learning ECG Words and Sentences via Pre-training ECG Language Model (ICLR 2025 · similarity 0.89)
- ECG-R1: Protocol-Guided and Modality-Agnostic MLLM for Reliable ECG Interpretation (ICML 2026 · similarity 0.88)
- From Token to Rhythm: A Multi-Scale Approach for ECG-Language Pretraining (ICML 2025 · similarity 0.88)
- GEM: Empowering MLLM for Grounded ECG Understanding with Time Series and Images (NeurIPS 2025 · similarity 0.87)
- anyECG-chat: A Generalist ECG-MLLM for Flexible ECG Input and Multi-Task Understanding (AAAI 2026 · similarity 0.87)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.