atlas

Research map / Time series / Foundation models for time series

GEM: Empowering MLLM for Grounded ECG Understanding with Time Series and Images

NeurIPS 2025 · Time series › Foundation models for time series · approach: Time-series language reasoning · 2 citations (OpenAlex)

Read the paperCheck your idea against 108,967 papers

AI-extracted summary. Written by AI from the paper's full text. Numbers and claims can be wrong or missing context, so check the paper before you cite or build on it.

Introduces GEM, an MLLM that fuses ECG time series and 12-lead ECG images with text, trained on a 30K GPT-4o-generated grounding dataset (ECG-Grounding) and evaluated on a new Grounded ECG Understanding task.

Problem

Existing language-based ECG models use only one non-text modality (time series or images) and provide little explainability linking diagnoses to granular waveform evidence.

Approach

A dual-encoder MLLM (ECG-CoCa time series encoder plus CLIP image encoder) with MLP projectors into the LLM token space, trained in one step on knowledge-guided instruction data where heartbeat-level feature sequences are fed to GPT-4o via a diagnosis guider to produce grounded answers.

Key results

Measured effects reported in the paper

What was changedWhereMeasuredEffect
Fine-tune with GEM's multimodal frameworkPULSE · MIMIC-IV-ECGDiagnosis Accuracy: 81.14 -> 86.49Helped
Fine-tune with GEM's multimodal frameworkPULSE · PTB-XLDiagnosis Accuracy: 59.24 -> 73.59Helped
Fine-tune with GEM's multimodal frameworkPULSE · MIMIC-IV-ECGECGFeatureGrounding: 50.18 -> 74.95Helped
Fine-tune with GEM's multimodal frameworkPULSE · PTB-XL SuperAUC: 82.4 -> 83.4Helped
Fine-tune with GEM's multimodal frameworkPULSE · ECG-QAAccuracy: 73.8 -> 73.6No clear effect
Add ECG images to time-series input (ablation)GEM · PTB-XL SuperAUC: 81.2 -> 82.7Helped
Add ECG images to time-series input (ablation)GEM · CODE-15%F1: 84.9 -> 86.3Helped
Add ECG images to time-series input (ablation)GEM · CPSC 2018F1: 54.0 -> 51.5Hurt
Add ECG images to time-series input (ablation)GEM · CSNACC: 91.6 -> 90.1Hurt
Add ECG images to time-series input (ablation)GEM · ECG-Bench abnormality detectionF1 / ACC: 84.9 -> 86.3; 54.0 -> 51.5; 91.6 -> 90.1Mixed

Surprising findings

Limitations

Experimental setup

Datasets: ECG-Instruct (PULSE) ECG-Grounding (MIMIC-IV-ECG derived) MIMIC-IV-ECG PTB-XL CPSC2018 G12EC CODE-15% CSN ECG-QA

Benchmarks: Grounded ECG Understanding (MIMIC-IV-ECG, PTB-XL) ECG-Bench (PTB-XL Super, CODE-15%, CPSC 2018, CSN, G12EC, PTB-XL Report, ECG-QA)

Metrics: diagnosis accuracy analysis completeness analysis relevance lead assessment coverage lead assessment accuracy ECG feature grounding evidence-based reasoning clinical diagnostic fidelity AUC F1

Baselines: PULSE GPT-4o ECG-Chat JoLT

Builds on: LLaVA PULSE ECG-CoCa

Closest papers by meaning

Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.

Open scime draft

Get the next scime Dispatch and a monthly field update

Free. We send a confirmation link first; every email has a one-click unsubscribe. Privacy