Proposes CG-Reasoner, a LLaVA-Med-based framework with a light-weight ConvNeXt-Tiny encoder-decoder and a Text2Centroid module that jointly produces medical segmentation masks and positional reasoning text, plus a new PRScore metric for reasoning-mask alignment.
Problem
Medical image segmentation models optimize pixel accuracy but neglect positional reasoning, and existing reasoning evaluations (ChatGPT yes/no judgments, BLEU/ROUGE) fail to check whether generated text correctly localizes the lesion.
Approach
Couple a LoRA-tuned multimodal LLM with a FiLM-conditioned lightweight decoder, and use a frozen Text2Centroid regressor that maps reasoning text to lesion centroid coordinates to supply a spatial grounding loss; evaluate with PRScore, which averages SBERT semantic similarity, text-derived spatial similarity, and text-to-mask centroid similarity.
Key results
- CG-Reasoner reaches mDice 0.977 / mIoU 0.958 on Lung X-ray, the best in its comparison, and 0.970 / 0.948 on Lung CT-Scan.
- PRScore on Breast Ultrasound is 0.755 for CG-Reasoner versus 0.729 for PRS-Med; PRS-Med is slightly higher on Polyp Endoscopy (0.734 vs 0.732) and Skin RGB (0.735 vs 0.730).
- Adding Text2Centroid raises PRScore across all six datasets (e.g., Breast Ultrasound 0.721 to 0.755).
Surprising findings
- CG-Reasoner has lower mDice than PRS-Med on Breast Ultrasound (0.765 vs 0.817) and lower than BiomedParse on Polyp Endoscopy in Table 2 comparisons, and it is also below PRS-Med on Polyp Endoscopy and Skin RGB PRScore.
Limitations
- PRScore relies on a Text2Centroid model whose own accuracy is not validated against human judgments.
- Gains over PRS-Med on segmentation are mixed; CG-Reasoner trails on Breast Ultrasound and Polyp Endoscopy.
- Ablations of the decoder and PRScore weighting choices are limited in the main text.
Experimental setup
Datasets: MMRS (PRS-Med combined dataset) Breast Ultrasound Brain MRI Lung CT-Scan Lung X-ray Polyp Endoscopy Skin RGB
Benchmarks: Breast Ultrasound Brain MRI Lung CT-Scan Lung X-ray Polyp Endoscopy Skin RGB Image
Metrics: mDice mIoU PRScore
Baselines: G-Dino + SAM-Med2D BiomedParse LISA-7B LISA-13B PRS-Med PixelLM Tiny-SAM Med-SAM Swin-UNet
Builds on: LISA LLaVA-Med ConvNeXt PRS-Med FiLM
Closest papers by meaning
- MedReasoner: Reinforcement Learning Drives Reasoning Grounding from Clinical Thought to Pixel-Level Precision (AAAI 2026 · similarity 0.89)
- CoPRS: Learning Positional Prior from Chain-of-Thought for Reasoning Segmentation (ICLR 2026 · similarity 0.86)
- CXReasonBench: A Benchmark for Evaluating Structured Diagnostic Reasoning in Chest X-rays (NeurIPS 2025 · similarity 0.86)
- IBISAgent: Reinforcing Pixel-Level Visual Reasoning in MLLMs for Universal Biomedical Object Referring and Segmentation (CVPR 2026 · similarity 0.85)
- "Why Is There a Tumor?": Tell Me the Reason, Show Me the Evidence (ICML 2025 · similarity 0.85)
- M3CoTBench: Benchmark Chain-of-Thought of MLLMs in Medical Image Understanding (ICLR 2026 · similarity 0.85)
Writing a paper in this area? scime draft is a free LaTeX editor with AI included, real-time co-authors and a check of your references and venue rules before you submit. It also imports OpenAI Prism projects.